power_supply: Add constant charge_current and charge_voltage properties

Constant Charge Current(CC) is charging parameter which limit the
maximum current which can be pumped into the battery during charge cycle.

Constant Charge Voltage(CV) is also charging parameter which limit the
maximum voltage that battery can reach during charge cycle.

It is very common practice that at low or high temperatures we
do not charge the batteries upto it's fullest charge voltage
to avoid battery and user safety issues.

These sysfs properties will be useful for debug and to implement
certain user space policies like "Charging limited due to OverTemp".

Signed-off-by: Ramakrishna Pallala <ramakrishna.pallala@intel.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
This commit is contained in:
Ramakrishna Pallala 2012-05-06 18:16:44 +05:30 committed by Anton Vorontsov
parent 3be330bf88
commit 3824c47714
3 changed files with 10 additions and 0 deletions

View File

@ -112,6 +112,10 @@ CHARGE_COUNTER - the current charge counter (in µAh). This could easily
be negative; there is no empty or full value. It is only useful for be negative; there is no empty or full value. It is only useful for
relative, time-based measurements. relative, time-based measurements.
CONSTANT_CHARGE_CURRENT - constant charge current programmed by charger.
CONSTANT_CHARGE_VOLTAGE - constant charge voltage programmed by charger.
ENERGY_FULL, ENERGY_EMPTY - same as above but for energy. ENERGY_FULL, ENERGY_EMPTY - same as above but for energy.
CAPACITY - capacity in percents. CAPACITY - capacity in percents.

View File

@ -159,6 +159,8 @@ static struct device_attribute power_supply_attrs[] = {
POWER_SUPPLY_ATTR(charge_now), POWER_SUPPLY_ATTR(charge_now),
POWER_SUPPLY_ATTR(charge_avg), POWER_SUPPLY_ATTR(charge_avg),
POWER_SUPPLY_ATTR(charge_counter), POWER_SUPPLY_ATTR(charge_counter),
POWER_SUPPLY_ATTR(constant_charge_current),
POWER_SUPPLY_ATTR(constant_charge_voltage),
POWER_SUPPLY_ATTR(energy_full_design), POWER_SUPPLY_ATTR(energy_full_design),
POWER_SUPPLY_ATTR(energy_empty_design), POWER_SUPPLY_ATTR(energy_empty_design),
POWER_SUPPLY_ATTR(energy_full), POWER_SUPPLY_ATTR(energy_full),

View File

@ -109,6 +109,8 @@ enum power_supply_property {
POWER_SUPPLY_PROP_CHARGE_NOW, POWER_SUPPLY_PROP_CHARGE_NOW,
POWER_SUPPLY_PROP_CHARGE_AVG, POWER_SUPPLY_PROP_CHARGE_AVG,
POWER_SUPPLY_PROP_CHARGE_COUNTER, POWER_SUPPLY_PROP_CHARGE_COUNTER,
POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT,
POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE,
POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN, POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN,
POWER_SUPPLY_PROP_ENERGY_EMPTY_DESIGN, POWER_SUPPLY_PROP_ENERGY_EMPTY_DESIGN,
POWER_SUPPLY_PROP_ENERGY_FULL, POWER_SUPPLY_PROP_ENERGY_FULL,
@ -239,6 +241,7 @@ static inline bool power_supply_is_amp_property(enum power_supply_property psp)
case POWER_SUPPLY_PROP_CHARGE_NOW: case POWER_SUPPLY_PROP_CHARGE_NOW:
case POWER_SUPPLY_PROP_CHARGE_AVG: case POWER_SUPPLY_PROP_CHARGE_AVG:
case POWER_SUPPLY_PROP_CHARGE_COUNTER: case POWER_SUPPLY_PROP_CHARGE_COUNTER:
case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT:
case POWER_SUPPLY_PROP_CURRENT_MAX: case POWER_SUPPLY_PROP_CURRENT_MAX:
case POWER_SUPPLY_PROP_CURRENT_NOW: case POWER_SUPPLY_PROP_CURRENT_NOW:
case POWER_SUPPLY_PROP_CURRENT_AVG: case POWER_SUPPLY_PROP_CURRENT_AVG:
@ -266,6 +269,7 @@ static inline bool power_supply_is_watt_property(enum power_supply_property psp)
case POWER_SUPPLY_PROP_VOLTAGE_NOW: case POWER_SUPPLY_PROP_VOLTAGE_NOW:
case POWER_SUPPLY_PROP_VOLTAGE_AVG: case POWER_SUPPLY_PROP_VOLTAGE_AVG:
case POWER_SUPPLY_PROP_VOLTAGE_OCV: case POWER_SUPPLY_PROP_VOLTAGE_OCV:
case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE:
case POWER_SUPPLY_PROP_POWER_NOW: case POWER_SUPPLY_PROP_POWER_NOW:
return 1; return 1;
default: default: