iio:bma180: Fix scale factors to report correct acceleration units
The userspace interface for acceleration sensors is documented as using
m/s^2 units [Documentation/ABI/testing/sysfs-bus-iio]
The fullscale raw values for the BMA80 corresponds to -/+ 1, 1.5, 2, etc G
depending on the selected mode.
The scale table was converting to G rather than m/s^2.
Change the scaling table to match the documented interface.
See commit 71702e6e
, iio: mma8452: Use correct acceleration units,
for a related fix.
Signed-off-by: Peter Meerwald <pmeerw@pmeerw.net>
Cc: Oleksandr Kravchenko <o.v.kravchenko@globallogic.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Cc: Stable@vger.kernel.org
This commit is contained in:
parent
61bd55ce16
commit
381676d5e8
|
@ -68,13 +68,13 @@
|
|||
/* Defaults values */
|
||||
#define BMA180_DEF_PMODE 0
|
||||
#define BMA180_DEF_BW 20
|
||||
#define BMA180_DEF_SCALE 250
|
||||
#define BMA180_DEF_SCALE 2452
|
||||
|
||||
/* Available values for sysfs */
|
||||
#define BMA180_FLP_FREQ_AVAILABLE \
|
||||
"10 20 40 75 150 300"
|
||||
#define BMA180_SCALE_AVAILABLE \
|
||||
"0.000130 0.000190 0.000250 0.000380 0.000500 0.000990 0.001980"
|
||||
"0.001275 0.001863 0.002452 0.003727 0.004903 0.009709 0.019417"
|
||||
|
||||
struct bma180_data {
|
||||
struct i2c_client *client;
|
||||
|
@ -94,7 +94,7 @@ enum bma180_axis {
|
|||
};
|
||||
|
||||
static int bw_table[] = { 10, 20, 40, 75, 150, 300 }; /* Hz */
|
||||
static int scale_table[] = { 130, 190, 250, 380, 500, 990, 1980 };
|
||||
static int scale_table[] = { 1275, 1863, 2452, 3727, 4903, 9709, 19417 };
|
||||
|
||||
static int bma180_get_acc_reg(struct bma180_data *data, enum bma180_axis axis)
|
||||
{
|
||||
|
|
Loading…
Reference in New Issue