MIPS: ralink: Fix invalid tick count
The current code adds the delta twice, which is obviously wrong. Signed-off-by: John Crispin <blogic@openwrt.org> Cc: linux-mips@linux-mips.org Patchwork: https://patchwork.linux-mips.org/patch/11443/ Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
This commit is contained in:
parent
73afa6c420
commit
37bcc03f97
|
@ -48,7 +48,7 @@ static int systick_next_event(unsigned long delta,
|
|||
sdev = container_of(evt, struct systick_device, dev);
|
||||
count = ioread32(sdev->membase + SYSTICK_COUNT);
|
||||
count = (count + delta) % SYSTICK_FREQ;
|
||||
iowrite32(count + delta, sdev->membase + SYSTICK_COMPARE);
|
||||
iowrite32(count, sdev->membase + SYSTICK_COMPARE);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
|