drivers: power: supply: goldfish_battery: Add support for reading more properties
To comply with tests we need to support more power supply properties: POWER_SUPPLY_PROP_VOLTAGE_NOW POWER_SUPPLY_PROP_TEMP POWER_SUPPLY_PROP_CHARGE_COUNTER POWER_SUPPLY_PROP_CURRENT_NOW POWER_SUPPLY_PROP_CURRENT_AVG POWER_SUPPLY_PROP_CHARGE_FULL POWER_SUPPLY_PROP_CYCLE_COUNT POWER_SUPPLY_PROP_VOLTAGE_MAX POWER_SUPPLY_PROP_CURRENT_MAX Signed-off-by: Roman Kiryanov <rkir@google.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
parent
02276af2fc
commit
2a7b0a29b3
|
@ -43,6 +43,15 @@ enum {
|
|||
BATTERY_HEALTH = 0x10,
|
||||
BATTERY_PRESENT = 0x14,
|
||||
BATTERY_CAPACITY = 0x18,
|
||||
BATTERY_VOLTAGE = 0x1C,
|
||||
BATTERY_TEMP = 0x20,
|
||||
BATTERY_CHARGE_COUNTER = 0x24,
|
||||
BATTERY_VOLTAGE_MAX = 0x28,
|
||||
BATTERY_CURRENT_MAX = 0x2C,
|
||||
BATTERY_CURRENT_NOW = 0x30,
|
||||
BATTERY_CURRENT_AVG = 0x34,
|
||||
BATTERY_CHARGE_FULL_UAH = 0x38,
|
||||
BATTERY_CYCLE_COUNT = 0x40,
|
||||
|
||||
BATTERY_STATUS_CHANGED = 1U << 0,
|
||||
AC_STATUS_CHANGED = 1U << 1,
|
||||
|
@ -61,6 +70,12 @@ static int goldfish_ac_get_property(struct power_supply *psy,
|
|||
case POWER_SUPPLY_PROP_ONLINE:
|
||||
val->intval = GOLDFISH_BATTERY_READ(data, BATTERY_AC_ONLINE);
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_VOLTAGE_MAX:
|
||||
val->intval = GOLDFISH_BATTERY_READ(data, BATTERY_VOLTAGE_MAX);
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_CURRENT_MAX:
|
||||
val->intval = GOLDFISH_BATTERY_READ(data, BATTERY_CURRENT_MAX);
|
||||
break;
|
||||
default:
|
||||
ret = -EINVAL;
|
||||
break;
|
||||
|
@ -91,6 +106,29 @@ static int goldfish_battery_get_property(struct power_supply *psy,
|
|||
case POWER_SUPPLY_PROP_CAPACITY:
|
||||
val->intval = GOLDFISH_BATTERY_READ(data, BATTERY_CAPACITY);
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_VOLTAGE_NOW:
|
||||
val->intval = GOLDFISH_BATTERY_READ(data, BATTERY_VOLTAGE);
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_TEMP:
|
||||
val->intval = GOLDFISH_BATTERY_READ(data, BATTERY_TEMP);
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_CHARGE_COUNTER:
|
||||
val->intval = GOLDFISH_BATTERY_READ(data,
|
||||
BATTERY_CHARGE_COUNTER);
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_CURRENT_NOW:
|
||||
val->intval = GOLDFISH_BATTERY_READ(data, BATTERY_CURRENT_NOW);
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_CURRENT_AVG:
|
||||
val->intval = GOLDFISH_BATTERY_READ(data, BATTERY_CURRENT_AVG);
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_CHARGE_FULL:
|
||||
val->intval = GOLDFISH_BATTERY_READ(data,
|
||||
BATTERY_CHARGE_FULL_UAH);
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_CYCLE_COUNT:
|
||||
val->intval = GOLDFISH_BATTERY_READ(data, BATTERY_CYCLE_COUNT);
|
||||
break;
|
||||
default:
|
||||
ret = -EINVAL;
|
||||
break;
|
||||
|
@ -105,10 +143,19 @@ static enum power_supply_property goldfish_battery_props[] = {
|
|||
POWER_SUPPLY_PROP_PRESENT,
|
||||
POWER_SUPPLY_PROP_TECHNOLOGY,
|
||||
POWER_SUPPLY_PROP_CAPACITY,
|
||||
POWER_SUPPLY_PROP_VOLTAGE_NOW,
|
||||
POWER_SUPPLY_PROP_TEMP,
|
||||
POWER_SUPPLY_PROP_CHARGE_COUNTER,
|
||||
POWER_SUPPLY_PROP_CURRENT_NOW,
|
||||
POWER_SUPPLY_PROP_CURRENT_AVG,
|
||||
POWER_SUPPLY_PROP_CHARGE_FULL,
|
||||
POWER_SUPPLY_PROP_CYCLE_COUNT,
|
||||
};
|
||||
|
||||
static enum power_supply_property goldfish_ac_props[] = {
|
||||
POWER_SUPPLY_PROP_ONLINE,
|
||||
POWER_SUPPLY_PROP_VOLTAGE_MAX,
|
||||
POWER_SUPPLY_PROP_CURRENT_MAX,
|
||||
};
|
||||
|
||||
static irqreturn_t goldfish_battery_interrupt(int irq, void *dev_id)
|
||||
|
|
Loading…
Reference in New Issue