ASoC: wm9712: Fix inverted capture volume

The capture volume increases with the register value so it shouldn't be
flagged as inverted.

Reported-by: Christoph Fritz <chf.fritz@googlemail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This commit is contained in:
Mark Brown 2012-07-31 18:37:28 +01:00
parent ccf795847a
commit 28c42c2830
1 changed files with 1 additions and 1 deletions

View File

@ -148,7 +148,7 @@ SOC_SINGLE("Treble Volume", AC97_MASTER_TONE, 0, 15, 1),
SOC_SINGLE("Capture ADC Switch", AC97_REC_GAIN, 15, 1, 1),
SOC_ENUM("Capture Volume Steps", wm9712_enum[6]),
SOC_DOUBLE("Capture Volume", AC97_REC_GAIN, 8, 0, 63, 1),
SOC_DOUBLE("Capture Volume", AC97_REC_GAIN, 8, 0, 63, 0),
SOC_SINGLE("Capture ZC Switch", AC97_REC_GAIN, 7, 1, 0),
SOC_SINGLE_TLV("Mic 1 Volume", AC97_MIC, 8, 31, 1, main_tlv),