ASoC: wm9712: Fix inverted capture volume
The capture volume increases with the register value so it shouldn't be flagged as inverted. Reported-by: Christoph Fritz <chf.fritz@googlemail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This commit is contained in:
parent
ccf795847a
commit
28c42c2830
|
@ -148,7 +148,7 @@ SOC_SINGLE("Treble Volume", AC97_MASTER_TONE, 0, 15, 1),
|
|||
|
||||
SOC_SINGLE("Capture ADC Switch", AC97_REC_GAIN, 15, 1, 1),
|
||||
SOC_ENUM("Capture Volume Steps", wm9712_enum[6]),
|
||||
SOC_DOUBLE("Capture Volume", AC97_REC_GAIN, 8, 0, 63, 1),
|
||||
SOC_DOUBLE("Capture Volume", AC97_REC_GAIN, 8, 0, 63, 0),
|
||||
SOC_SINGLE("Capture ZC Switch", AC97_REC_GAIN, 7, 1, 0),
|
||||
|
||||
SOC_SINGLE_TLV("Mic 1 Volume", AC97_MIC, 8, 31, 1, main_tlv),
|
||||
|
|
Loading…
Reference in New Issue