HID: logitech-hidpp: battery: provide ONLINE property

When ONLINE isn't set, upower should ignore the battery capacity,
so there is no need to overload it with some random values.

Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Tested-by: Bastien Nocera <hadess@hadess.net>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This commit is contained in:
Benjamin Tissoires 2017-03-27 16:59:34 +02:00 committed by Jiri Kosina
parent 9b9c519f1f
commit 284f8d7592
1 changed files with 20 additions and 11 deletions

View File

@ -120,6 +120,7 @@ struct hidpp_battery {
char name[64];
int status;
int level;
bool online;
};
struct hidpp_device {
@ -686,7 +687,6 @@ static int hidpp20_batterylevel_map_status_level(u8 data[3], int *level,
int *next_level)
{
int status;
int level_override;
*level = data[0];
*next_level = data[1];
@ -698,36 +698,28 @@ static int hidpp20_batterylevel_map_status_level(u8 data[3], int *level,
switch (data[2]) {
case 0: /* discharging (in use) */
status = POWER_SUPPLY_STATUS_DISCHARGING;
level_override = 0;
break;
case 1: /* recharging */
status = POWER_SUPPLY_STATUS_CHARGING;
level_override = 80;
break;
case 2: /* charge in final stage */
status = POWER_SUPPLY_STATUS_CHARGING;
level_override = 90;
break;
case 3: /* charge complete */
status = POWER_SUPPLY_STATUS_FULL;
level_override = 100;
*level = 100;
break;
case 4: /* recharging below optimal speed */
status = POWER_SUPPLY_STATUS_CHARGING;
level_override = 50;
break;
/* 5 = invalid battery type
6 = thermal error
7 = other charging error */
default:
status = POWER_SUPPLY_STATUS_NOT_CHARGING;
level_override = 0;
break;
}
if (level_override != 0 && *level == 0)
*level = level_override;
return status;
}
@ -781,6 +773,9 @@ static int hidpp20_query_battery_info(struct hidpp_device *hidpp)
hidpp->battery.status = status;
hidpp->battery.level = level;
/* the capacity is only available when discharging or full */
hidpp->battery.online = status == POWER_SUPPLY_STATUS_DISCHARGING ||
status == POWER_SUPPLY_STATUS_FULL;
return 0;
}
@ -799,6 +794,10 @@ static int hidpp20_battery_event(struct hidpp_device *hidpp,
status = hidpp20_batterylevel_map_status_level(report->fap.params,
&level, &next_level);
/* the capacity is only available when discharging or full */
hidpp->battery.online = status == POWER_SUPPLY_STATUS_DISCHARGING ||
status == POWER_SUPPLY_STATUS_FULL;
changed = level != hidpp->battery.level ||
status != hidpp->battery.status;
@ -813,6 +812,7 @@ static int hidpp20_battery_event(struct hidpp_device *hidpp,
}
static enum power_supply_property hidpp_battery_props[] = {
POWER_SUPPLY_PROP_ONLINE,
POWER_SUPPLY_PROP_STATUS,
POWER_SUPPLY_PROP_CAPACITY,
POWER_SUPPLY_PROP_SCOPE,
@ -838,6 +838,9 @@ static int hidpp_battery_get_property(struct power_supply *psy,
case POWER_SUPPLY_PROP_SCOPE:
val->intval = POWER_SUPPLY_SCOPE_DEVICE;
break;
case POWER_SUPPLY_PROP_ONLINE:
val->intval = hidpp->battery.online;
break;
case POWER_SUPPLY_PROP_MODEL_NAME:
if (!strncmp(hidpp->name, "Logitech ", 9))
val->strval = hidpp->name + 9;
@ -2416,8 +2419,14 @@ static void hidpp_connect_event(struct hidpp_device *hidpp)
struct input_dev *input;
char *name, *devm_name;
if (!connected)
if (!connected) {
if (hidpp->battery.ps) {
hidpp->battery.online = false;
hidpp->battery.status = POWER_SUPPLY_STATUS_UNKNOWN;
power_supply_changed(hidpp->battery.ps);
}
return;
}
if (hidpp->quirks & HIDPP_QUIRK_CLASS_WTP) {
ret = wtp_connect(hdev, connected);