arm64: dts: mt8173: fix cooling device range
When thermal reaches target temperature,it would be pinned to state 0 (max frequency and power). Fix the throttling range to no limit. Signed-off-by: Hsin-Yi Wang <hsinyi@chromium.org> Signed-off-by: Michael Kao <michael.kao@mediatek.com> Link: https://lore.kernel.org/r/20200424082340.4127-1-michael.kao@mediatek.com Signed-off-by: Matthias Brugger <matthias.bgg@gmail.com>
This commit is contained in:
parent
689b937bed
commit
26af2884e4
|
@ -19,6 +19,7 @@
|
|||
#include <dt-bindings/power/mt8173-power.h>
|
||||
#include <dt-bindings/reset/mt8173-resets.h>
|
||||
#include <dt-bindings/gce/mt8173-gce.h>
|
||||
#include <dt-bindings/thermal/thermal.h>
|
||||
#include "mt8173-pinfunc.h"
|
||||
|
||||
/ {
|
||||
|
@ -298,14 +299,18 @@
|
|||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&target>;
|
||||
cooling-device = <&cpu0 0 0>,
|
||||
<&cpu1 0 0>;
|
||||
cooling-device = <&cpu0 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>,
|
||||
<&cpu1 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
contribution = <3072>;
|
||||
};
|
||||
map1 {
|
||||
trip = <&target>;
|
||||
cooling-device = <&cpu2 0 0>,
|
||||
<&cpu3 0 0>;
|
||||
cooling-device = <&cpu2 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>,
|
||||
<&cpu3 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
contribution = <1024>;
|
||||
};
|
||||
};
|
||||
|
|
Loading…