net: mvpp2: set 802.3x GoP Flow Control mode

This patch fix GMAC TX flow control autoneg.
Flow control autoneg wrongly were disabled with enabled TX
flow control.

Signed-off-by: Stefan Chulski <stefanc@marvell.com>
Acked-by: Marcin Wojtas <mw@semihalf.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Stefan Chulski 2021-02-11 12:49:01 +02:00 committed by David S. Miller
parent aca0e23584
commit 262412d55a
1 changed files with 1 additions and 1 deletions

View File

@ -6284,7 +6284,7 @@ static void mvpp2_gmac_config(struct mvpp2_port *port, unsigned int mode,
old_ctrl4 = ctrl4 = readl(port->base + MVPP22_GMAC_CTRL_4_REG);
ctrl0 &= ~MVPP2_GMAC_PORT_TYPE_MASK;
ctrl2 &= ~(MVPP2_GMAC_INBAND_AN_MASK | MVPP2_GMAC_PCS_ENABLE_MASK);
ctrl2 &= ~(MVPP2_GMAC_INBAND_AN_MASK | MVPP2_GMAC_PCS_ENABLE_MASK | MVPP2_GMAC_FLOW_CTRL_MASK);
/* Configure port type */
if (phy_interface_mode_is_8023z(state->interface)) {