scsi: virtio_scsi: Always try to read VPD pages

Passed through SCSI targets may have transfer limits which come from the
host SCSI controller or something on the host side other than the target
itself.

To make this work properly, the hypervisor can adjust the target's VPD
information to advertise these limits.  But for that to work, the guest
has to look at the VPD pages, which we won't do by default if it is an
SPC-2 device, even if it does actually support it.

This adds a workaround to address this, forcing devices attached to a
virtio-scsi controller to always check the VPD pages.  This is modelled
on a similar workaround for the storvsc (Hyper-V) SCSI controller,
although that exists for slightly different reasons.

A specific case which causes this is a volume from IBM's IPR RAID
controller (which presents as an SPC-2 device, although it does support
VPD) passed through with qemu's 'scsi-block' device.

[mkp: fixed typo]

Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Acked-by: Paolo Bonzini <pbonzini@redhat.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
This commit is contained in:
David Gibson 2017-04-13 12:13:00 +10:00 committed by Martin K. Petersen
parent ea98ab34c4
commit 25d1d50e23
1 changed files with 24 additions and 0 deletions

View File

@ -29,6 +29,7 @@
#include <scsi/scsi_device.h> #include <scsi/scsi_device.h>
#include <scsi/scsi_cmnd.h> #include <scsi/scsi_cmnd.h>
#include <scsi/scsi_tcq.h> #include <scsi/scsi_tcq.h>
#include <scsi/scsi_devinfo.h>
#include <linux/seqlock.h> #include <linux/seqlock.h>
#include <linux/blk-mq-virtio.h> #include <linux/blk-mq-virtio.h>
@ -705,6 +706,28 @@ static int virtscsi_device_reset(struct scsi_cmnd *sc)
return virtscsi_tmf(vscsi, cmd); return virtscsi_tmf(vscsi, cmd);
} }
static int virtscsi_device_alloc(struct scsi_device *sdevice)
{
/*
* Passed through SCSI targets (e.g. with qemu's 'scsi-block')
* may have transfer limits which come from the host SCSI
* controller or something on the host side other than the
* target itself.
*
* To make this work properly, the hypervisor can adjust the
* target's VPD information to advertise these limits. But
* for that to work, the guest has to look at the VPD pages,
* which we won't do by default if it is an SPC-2 device, even
* if it does actually support it.
*
* So, set the blist to always try to read the VPD pages.
*/
sdevice->sdev_bflags = BLIST_TRY_VPD_PAGES;
return 0;
}
/** /**
* virtscsi_change_queue_depth() - Change a virtscsi target's queue depth * virtscsi_change_queue_depth() - Change a virtscsi target's queue depth
* @sdev: Virtscsi target whose queue depth to change * @sdev: Virtscsi target whose queue depth to change
@ -783,6 +806,7 @@ static struct scsi_host_template virtscsi_host_template_single = {
.change_queue_depth = virtscsi_change_queue_depth, .change_queue_depth = virtscsi_change_queue_depth,
.eh_abort_handler = virtscsi_abort, .eh_abort_handler = virtscsi_abort,
.eh_device_reset_handler = virtscsi_device_reset, .eh_device_reset_handler = virtscsi_device_reset,
.slave_alloc = virtscsi_device_alloc,
.can_queue = 1024, .can_queue = 1024,
.dma_boundary = UINT_MAX, .dma_boundary = UINT_MAX,