xhci: use completion event's slot id rather than dig it out of command
Since the slot id retrieved from the Reset Device TRB matches the slot id in the command completion event, which is available, there is no need to determine it again. This patch removes the uneccessary reassignment to slot id and adds a WARN_ON in case the two Slot ID fields differ (although according xhci spec rev1.0 they should not differ). Signed-off-by: Xenia Ragiadakou <burzalodowa@gmail.com> Signed-off-by: Sarah Sharp <sarah.a.sharp@linux.intel.com>
This commit is contained in:
parent
9b3103ac9d
commit
20e7acb13f
|
@ -1547,9 +1547,9 @@ bandwidth_change:
|
|||
xhci_handle_cmd_reset_ep(xhci, event, xhci->cmd_ring->dequeue);
|
||||
break;
|
||||
case TRB_TYPE(TRB_RESET_DEV):
|
||||
WARN_ON(slot_id != TRB_TO_SLOT_ID(
|
||||
le32_to_cpu(xhci->cmd_ring->dequeue->generic.field[3])));
|
||||
xhci_dbg(xhci, "Completed reset device command.\n");
|
||||
slot_id = TRB_TO_SLOT_ID(
|
||||
le32_to_cpu(xhci->cmd_ring->dequeue->generic.field[3]));
|
||||
virt_dev = xhci->devs[slot_id];
|
||||
if (virt_dev)
|
||||
handle_cmd_in_cmd_wait_list(xhci, virt_dev, event);
|
||||
|
|