ASoC: wm8960: Fix wrong clock after suspend & resume
After suspend & resume, wm8960_hw_params may be called when
bias_level is not SND_SOC_BIAS_ON, then wm8960_configure_clocking
is not called. But if sample rate is changed at that time, then
the output clock rate will be not correct.
So judgement of bias_level is SND_SOC_BIAS_ON in wm8960_hw_params
is not necessary and it causes above issue.
Fixes: 3176bf2d7c
("ASoC: wm8960: update pll and clock setting function")
Signed-off-by: Shengjiu Wang <shengjiu.wang@nxp.com>
Acked-by: Charles Keepax <ckeepax@opensource.cirrus.com>
Link: https://lore.kernel.org/r/1587468525-27514-1-git-send-email-shengjiu.wang@nxp.com
Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
parent
9bff3d3024
commit
1e060a453c
|
@ -860,8 +860,7 @@ static int wm8960_hw_params(struct snd_pcm_substream *substream,
|
|||
|
||||
wm8960->is_stream_in_use[tx] = true;
|
||||
|
||||
if (snd_soc_component_get_bias_level(component) == SND_SOC_BIAS_ON &&
|
||||
!wm8960->is_stream_in_use[!tx])
|
||||
if (!wm8960->is_stream_in_use[!tx])
|
||||
return wm8960_configure_clocking(component);
|
||||
|
||||
return 0;
|
||||
|
|