thermal: rockchip: fix calculation error for code_to_temp

the calculation use a global table, not their own table.
so adapt the table to the correct one.

Signed-off-by: Elaine Zhang <zhangqing@rock-chips.com>
Signed-off-by: Caesar Wang <wxt@rock-chips.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
Elaine Zhang 2016-02-15 15:33:29 +08:00 committed by Eduardo Valentin
parent 43b4eb9fe7
commit 1d37a037dd
1 changed files with 1 additions and 1 deletions

View File

@ -411,7 +411,7 @@ static int rk_tsadcv2_code_to_temp(struct chip_tsadc_table table, u32 code,
* temperature between 2 table entries is linear and interpolate
* to produce less granular result.
*/
num = table.id[mid].temp - v2_code_table[mid - 1].temp;
num = table.id[mid].temp - table.id[mid - 1].temp;
num *= abs(table.id[mid - 1].code - code);
denom = abs(table.id[mid - 1].code - table.id[mid].code);
*temp = table.id[mid - 1].temp + (num / denom);