thermal: rockchip: fix calculation error for code_to_temp
the calculation use a global table, not their own table. so adapt the table to the correct one. Signed-off-by: Elaine Zhang <zhangqing@rock-chips.com> Signed-off-by: Caesar Wang <wxt@rock-chips.com> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
parent
43b4eb9fe7
commit
1d37a037dd
|
@ -411,7 +411,7 @@ static int rk_tsadcv2_code_to_temp(struct chip_tsadc_table table, u32 code,
|
|||
* temperature between 2 table entries is linear and interpolate
|
||||
* to produce less granular result.
|
||||
*/
|
||||
num = table.id[mid].temp - v2_code_table[mid - 1].temp;
|
||||
num = table.id[mid].temp - table.id[mid - 1].temp;
|
||||
num *= abs(table.id[mid - 1].code - code);
|
||||
denom = abs(table.id[mid - 1].code - table.id[mid].code);
|
||||
*temp = table.id[mid - 1].temp + (num / denom);
|
||||
|
|
Loading…
Reference in New Issue