net/mlx5e: Verify flow_source cap before using it
When adding send to vport rule verify flow_source matching is
supported by checking the flow_source cap.
Fixes: d044425403
("net/mlx5: E-Switch, set flow source for send to uplink rule")
Signed-off-by: Roi Dayan <roid@nvidia.com>
Reviewed-by: Maor Dickman <maord@nvidia.com>
Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>
This commit is contained in:
parent
e1ed30c8c0
commit
1bf8b0dae8
|
@ -869,7 +869,8 @@ mlx5_eswitch_add_send_to_vport_rule(struct mlx5_eswitch *on_esw,
|
|||
dest.vport.flags |= MLX5_FLOW_DEST_VPORT_VHCA_ID;
|
||||
flow_act.action = MLX5_FLOW_CONTEXT_ACTION_FWD_DEST;
|
||||
|
||||
if (rep->vport == MLX5_VPORT_UPLINK)
|
||||
if (MLX5_CAP_ESW_FLOWTABLE(on_esw->dev, flow_source) &&
|
||||
rep->vport == MLX5_VPORT_UPLINK)
|
||||
spec->flow_context.flow_source = MLX5_FLOW_CONTEXT_FLOW_SOURCE_LOCAL_VPORT;
|
||||
|
||||
flow_rule = mlx5_add_flow_rules(mlx5_eswitch_get_slow_fdb(on_esw),
|
||||
|
|