clocksource/drivers/sh_cmt: Document "cmt-48" as deprecated

Update the CMT driver to mark "renesas,cmt-48" as deprecated.

Instead of documenting a theoretical hardware device based on current software
support level, define DT bindings top-down based on available data sheet
information and make use of part numbers in the DT compat string.

In case of the only in-tree users r8a7740 and sh73a0 the compat strings
"renesas,r8a7740-cmt1" and "renesas,sh73a0-cmt1" may be used instead.

Signed-off-by: Magnus Damm <damm+renesas@opensource.se>
Reviewed-by: Simon Horman <horms+renesas@verge.net.au>
Reviewed-by: Geert Uytterhoeven <geert+renesas@glider.be>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
This commit is contained in:
Magnus Damm 2019-08-20 21:36:07 +09:00 committed by Daniel Lezcano
parent 8c1afba285
commit 19d608458f
1 changed files with 5 additions and 1 deletions

View File

@ -918,7 +918,11 @@ static const struct platform_device_id sh_cmt_id_table[] = {
MODULE_DEVICE_TABLE(platform, sh_cmt_id_table);
static const struct of_device_id sh_cmt_of_table[] __maybe_unused = {
{ .compatible = "renesas,cmt-48", .data = &sh_cmt_info[SH_CMT_48BIT] },
{
/* deprecated, preserved for backward compatibility */
.compatible = "renesas,cmt-48",
.data = &sh_cmt_info[SH_CMT_48BIT]
},
{
/* deprecated, preserved for backward compatibility */
.compatible = "renesas,cmt-48-gen2",