gre: fix TUNNEL_SEQ bit check on sequence numbering
The current logic of flags | TUNNEL_SEQ is always non-zero and hence
sequence numbers are always incremented no matter the setting of the
TUNNEL_SEQ bit. Fix this by using & instead of |.
Detected by CoverityScan, CID#1466039 ("Operands don't affect result")
Fixes: 77a5196a80
("gre: add sequence number for collect md mode.")
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Acked-by: William Tu <u9012063@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
faf4db0081
commit
1574639411
|
@ -550,7 +550,7 @@ static void gre_fb_xmit(struct sk_buff *skb, struct net_device *dev,
|
|||
(TUNNEL_CSUM | TUNNEL_KEY | TUNNEL_SEQ);
|
||||
gre_build_header(skb, tunnel_hlen, flags, proto,
|
||||
tunnel_id_to_key32(tun_info->key.tun_id),
|
||||
(flags | TUNNEL_SEQ) ? htonl(tunnel->o_seqno++) : 0);
|
||||
(flags & TUNNEL_SEQ) ? htonl(tunnel->o_seqno++) : 0);
|
||||
|
||||
df = key->tun_flags & TUNNEL_DONT_FRAGMENT ? htons(IP_DF) : 0;
|
||||
|
||||
|
|
|
@ -724,7 +724,7 @@ static netdev_tx_t __gre6_xmit(struct sk_buff *skb,
|
|||
gre_build_header(skb, tunnel->tun_hlen,
|
||||
flags, protocol,
|
||||
tunnel_id_to_key32(tun_info->key.tun_id),
|
||||
(flags | TUNNEL_SEQ) ? htonl(tunnel->o_seqno++)
|
||||
(flags & TUNNEL_SEQ) ? htonl(tunnel->o_seqno++)
|
||||
: 0);
|
||||
|
||||
} else {
|
||||
|
|