omap: iommu-load cam register before flushing the entry
The flush_iotlb_page is not loading the cam register before flushing the cam entry. This causes wrong entry to be flushed out from the TLB, and if the entry happens to be a locked TLB entry it would lead to MMU faults. The fix is to load the cam register with the address to be flushed before flushing the TLB entry. Signed-off-by: Hari Kanigeri <h-kanigeri2@ti.com> Acked-by: Hiroshi DOYU <Hiroshi.DOYU@nokia.com> Signed-off-by: Tony Lindgren <tony@atomide.com>
This commit is contained in:
parent
3c729087d4
commit
0fa035e523
|
@ -320,6 +320,7 @@ void flush_iotlb_page(struct iommu *obj, u32 da)
|
|||
if ((start <= da) && (da < start + bytes)) {
|
||||
dev_dbg(obj->dev, "%s: %08x<=%08x(%x)\n",
|
||||
__func__, start, da, bytes);
|
||||
iotlb_load_cr(obj, &cr);
|
||||
iommu_write_reg(obj, 1, MMU_FLUSH_ENTRY);
|
||||
}
|
||||
}
|
||||
|
|
Loading…