2019-05-20 15:19:02 +08:00
|
|
|
/* SPDX-License-Identifier: GPL-2.0-or-later */
|
2005-04-17 06:20:36 +08:00
|
|
|
/*
|
|
|
|
lm75.h - Part of lm_sensors, Linux kernel modules for hardware
|
2012-01-05 06:16:39 +08:00
|
|
|
monitoring
|
2005-04-17 06:20:36 +08:00
|
|
|
Copyright (c) 2003 Mark M. Hoffman <mhoffman@lightlink.com>
|
|
|
|
|
|
|
|
*/
|
|
|
|
|
|
|
|
/*
|
|
|
|
This file contains common code for encoding/decoding LM75 type
|
|
|
|
temperature readings, which are emulated by many of the chips
|
|
|
|
we support. As the user is unlikely to load more than one driver
|
|
|
|
which contains this code, we don't worry about the wasted space.
|
|
|
|
*/
|
|
|
|
|
2013-03-19 04:19:49 +08:00
|
|
|
#include <linux/kernel.h>
|
2005-04-17 06:20:36 +08:00
|
|
|
|
|
|
|
/* straight from the datasheet */
|
|
|
|
#define LM75_TEMP_MIN (-55000)
|
|
|
|
#define LM75_TEMP_MAX 125000
|
2010-08-15 03:08:50 +08:00
|
|
|
#define LM75_SHUTDOWN 0x01
|
2005-04-17 06:20:36 +08:00
|
|
|
|
|
|
|
/* TEMP: 0.001C/bit (-55C to +125C)
|
|
|
|
REG: (0.5C/bit, two's complement) << 7 */
|
2007-08-16 17:40:10 +08:00
|
|
|
static inline u16 LM75_TEMP_TO_REG(long temp)
|
2005-04-17 06:20:36 +08:00
|
|
|
{
|
2013-01-10 00:09:34 +08:00
|
|
|
int ntemp = clamp_val(temp, LM75_TEMP_MIN, LM75_TEMP_MAX);
|
2012-01-05 06:16:39 +08:00
|
|
|
ntemp += (ntemp < 0 ? -250 : 250);
|
2005-04-17 06:20:36 +08:00
|
|
|
return (u16)((ntemp / 500) << 7);
|
|
|
|
}
|
|
|
|
|
|
|
|
static inline int LM75_TEMP_FROM_REG(u16 reg)
|
|
|
|
{
|
|
|
|
/* use integer division instead of equivalent right shift to
|
|
|
|
guarantee arithmetic shift and preserve the sign */
|
|
|
|
return ((s16)reg / 128) * 500;
|
|
|
|
}
|