OpenCloudOS-Kernel/drivers/thermal/gov_bang_bang.c

129 lines
3.5 KiB
C
Raw Normal View History

// SPDX-License-Identifier: GPL-2.0-only
/*
* gov_bang_bang.c - A simple thermal throttling governor using hysteresis
*
* Copyright (C) 2014 Peter Feuerer <peter@piie.net>
*
* Based on step_wise.c with following Copyrights:
* Copyright (C) 2012 Intel Corp
* Copyright (C) 2012 Durgadoss R <durgadoss.r@intel.com>
*/
#include <linux/thermal.h>
#include "thermal_core.h"
static void thermal_zone_trip_update(struct thermal_zone_device *tz, int trip)
{
thermal: consistently use int for temperatures The thermal code uses int, long and unsigned long for temperatures in different places. Using an unsigned type limits the thermal framework to positive temperatures without need. Also several drivers currently will report temperatures near UINT_MAX for temperatures below 0°C. This will probably immediately shut the machine down due to overtemperature if started below 0°C. 'long' is 64bit on several architectures. This is not needed since INT_MAX °mC is above the melting point of all known materials. Consistently use a plain 'int' for temperatures throughout the thermal code and the drivers. This only changes the places in the drivers where the temperature is passed around as pointer, when drivers internally use another type this is not changed. Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de> Acked-by: Geert Uytterhoeven <geert+renesas@glider.be> Reviewed-by: Jean Delvare <jdelvare@suse.de> Reviewed-by: Lukasz Majewski <l.majewski@samsung.com> Reviewed-by: Darren Hart <dvhart@linux.intel.com> Reviewed-by: Heiko Stuebner <heiko@sntech.de> Reviewed-by: Peter Feuerer <peter@piie.net> Cc: Punit Agrawal <punit.agrawal@arm.com> Cc: Zhang Rui <rui.zhang@intel.com> Cc: Eduardo Valentin <edubezval@gmail.com> Cc: linux-pm@vger.kernel.org Cc: linux-kernel@vger.kernel.org Cc: Jean Delvare <jdelvare@suse.de> Cc: Peter Feuerer <peter@piie.net> Cc: Heiko Stuebner <heiko@sntech.de> Cc: Lukasz Majewski <l.majewski@samsung.com> Cc: Stephen Warren <swarren@wwwdotorg.org> Cc: Thierry Reding <thierry.reding@gmail.com> Cc: linux-acpi@vger.kernel.org Cc: platform-driver-x86@vger.kernel.org Cc: linux-arm-kernel@lists.infradead.org Cc: linux-omap@vger.kernel.org Cc: linux-samsung-soc@vger.kernel.org Cc: Guenter Roeck <linux@roeck-us.net> Cc: Rafael J. Wysocki <rjw@rjwysocki.net> Cc: Maxime Ripard <maxime.ripard@free-electrons.com> Cc: Darren Hart <dvhart@infradead.org> Cc: lm-sensors@lm-sensors.org Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2015-07-24 14:12:54 +08:00
int trip_temp, trip_hyst;
struct thermal_instance *instance;
tz->ops->get_trip_temp(tz, trip, &trip_temp);
if (!tz->ops->get_trip_hyst) {
pr_warn_once("Undefined get_trip_hyst for thermal zone %s - "
"running with default hysteresis zero\n", tz->type);
trip_hyst = 0;
} else
tz->ops->get_trip_hyst(tz, trip, &trip_hyst);
thermal: consistently use int for temperatures The thermal code uses int, long and unsigned long for temperatures in different places. Using an unsigned type limits the thermal framework to positive temperatures without need. Also several drivers currently will report temperatures near UINT_MAX for temperatures below 0°C. This will probably immediately shut the machine down due to overtemperature if started below 0°C. 'long' is 64bit on several architectures. This is not needed since INT_MAX °mC is above the melting point of all known materials. Consistently use a plain 'int' for temperatures throughout the thermal code and the drivers. This only changes the places in the drivers where the temperature is passed around as pointer, when drivers internally use another type this is not changed. Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de> Acked-by: Geert Uytterhoeven <geert+renesas@glider.be> Reviewed-by: Jean Delvare <jdelvare@suse.de> Reviewed-by: Lukasz Majewski <l.majewski@samsung.com> Reviewed-by: Darren Hart <dvhart@linux.intel.com> Reviewed-by: Heiko Stuebner <heiko@sntech.de> Reviewed-by: Peter Feuerer <peter@piie.net> Cc: Punit Agrawal <punit.agrawal@arm.com> Cc: Zhang Rui <rui.zhang@intel.com> Cc: Eduardo Valentin <edubezval@gmail.com> Cc: linux-pm@vger.kernel.org Cc: linux-kernel@vger.kernel.org Cc: Jean Delvare <jdelvare@suse.de> Cc: Peter Feuerer <peter@piie.net> Cc: Heiko Stuebner <heiko@sntech.de> Cc: Lukasz Majewski <l.majewski@samsung.com> Cc: Stephen Warren <swarren@wwwdotorg.org> Cc: Thierry Reding <thierry.reding@gmail.com> Cc: linux-acpi@vger.kernel.org Cc: platform-driver-x86@vger.kernel.org Cc: linux-arm-kernel@lists.infradead.org Cc: linux-omap@vger.kernel.org Cc: linux-samsung-soc@vger.kernel.org Cc: Guenter Roeck <linux@roeck-us.net> Cc: Rafael J. Wysocki <rjw@rjwysocki.net> Cc: Maxime Ripard <maxime.ripard@free-electrons.com> Cc: Darren Hart <dvhart@infradead.org> Cc: lm-sensors@lm-sensors.org Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2015-07-24 14:12:54 +08:00
dev_dbg(&tz->device, "Trip%d[temp=%d]:temp=%d:hyst=%d\n",
trip, trip_temp, tz->temperature,
trip_hyst);
mutex_lock(&tz->lock);
list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
if (instance->trip != trip)
continue;
/* in case fan is in initial state, switch the fan off */
if (instance->target == THERMAL_NO_TARGET)
instance->target = 0;
/* in case fan is neither on nor off set the fan to active */
if (instance->target != 0 && instance->target != 1) {
pr_warn("Thermal instance %s controlled by bang-bang has unexpected state: %ld\n",
instance->name, instance->target);
instance->target = 1;
}
/*
* enable fan when temperature exceeds trip_temp and disable
* the fan in case it falls below trip_temp minus hysteresis
*/
if (instance->target == 0 && tz->temperature >= trip_temp)
instance->target = 1;
else if (instance->target == 1 &&
tz->temperature <= trip_temp - trip_hyst)
instance->target = 0;
dev_dbg(&instance->cdev->device, "target=%d\n",
(int)instance->target);
thermal: fix race condition when updating cooling device When multiple thermal zones are bound to the same cooling device, multiple kernel threads may want to update the cooling device state by calling thermal_cdev_update(). Having cdev not protected by a mutex can lead to a race condition. Consider the following situation with two kernel threads k1 and k2: Thread k1 Thread k2 || || call thermal_cdev_update() || ... || set_cur_state(cdev, target); call power_actor_set_power() || ... || instance->target = state; || cdev->updated = false; || || cdev->updated = true; || // completes execution call thermal_cdev_update() || // cdev->updated == true || return; || \/ time k2 has already looped through the thermal instances looking for the deepest cooling device state and is preempted right before setting cdev->updated to true. Now, k1 runs, modifies the thermal instance state and sets cdev->updated to false. Then, k1 is preempted and k2 continues the execution by setting cdev->updated to true, therefore preventing k1 from performing the update. Notice that this is not an issue if k2 looks at the instance->target modified by k1 "after" it is assigned by k1. In fact, in this case the update will happen anyway and k1 can safely return immediately from thermal_cdev_update(). This may lead to a situation where a thermal governor never updates the cooling device. For example, this is the case for the step_wise governor: when calling the function thermal_zone_trip_update(), the governor may always get a new state equal to the old one (which, however, wasn't notified to the cooling device) and will therefore skip the update. CC: Zhang Rui <rui.zhang@intel.com> CC: Eduardo Valentin <edubezval@gmail.com> CC: Peter Feuerer <peter@piie.net> Reported-by: Toby Huang <toby.huang@arm.com> Signed-off-by: Michele Di Giorgio <michele.digiorgio@arm.com> Reviewed-by: Javi Merino <javi.merino@arm.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2016-06-02 22:25:31 +08:00
mutex_lock(&instance->cdev->lock);
instance->cdev->updated = false; /* cdev needs update */
thermal: fix race condition when updating cooling device When multiple thermal zones are bound to the same cooling device, multiple kernel threads may want to update the cooling device state by calling thermal_cdev_update(). Having cdev not protected by a mutex can lead to a race condition. Consider the following situation with two kernel threads k1 and k2: Thread k1 Thread k2 || || call thermal_cdev_update() || ... || set_cur_state(cdev, target); call power_actor_set_power() || ... || instance->target = state; || cdev->updated = false; || || cdev->updated = true; || // completes execution call thermal_cdev_update() || // cdev->updated == true || return; || \/ time k2 has already looped through the thermal instances looking for the deepest cooling device state and is preempted right before setting cdev->updated to true. Now, k1 runs, modifies the thermal instance state and sets cdev->updated to false. Then, k1 is preempted and k2 continues the execution by setting cdev->updated to true, therefore preventing k1 from performing the update. Notice that this is not an issue if k2 looks at the instance->target modified by k1 "after" it is assigned by k1. In fact, in this case the update will happen anyway and k1 can safely return immediately from thermal_cdev_update(). This may lead to a situation where a thermal governor never updates the cooling device. For example, this is the case for the step_wise governor: when calling the function thermal_zone_trip_update(), the governor may always get a new state equal to the old one (which, however, wasn't notified to the cooling device) and will therefore skip the update. CC: Zhang Rui <rui.zhang@intel.com> CC: Eduardo Valentin <edubezval@gmail.com> CC: Peter Feuerer <peter@piie.net> Reported-by: Toby Huang <toby.huang@arm.com> Signed-off-by: Michele Di Giorgio <michele.digiorgio@arm.com> Reviewed-by: Javi Merino <javi.merino@arm.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2016-06-02 22:25:31 +08:00
mutex_unlock(&instance->cdev->lock);
}
mutex_unlock(&tz->lock);
}
/**
* bang_bang_control - controls devices associated with the given zone
* @tz - thermal_zone_device
* @trip - the trip point
*
* Regulation Logic: a two point regulation, deliver cooling state depending
* on the previous state shown in this diagram:
*
* Fan: OFF ON
*
* |
* |
* trip_temp: +---->+
* | | ^
* | | |
* | | Temperature
* (trip_temp - hyst): +<----+
* |
* |
* |
*
* * If the fan is not running and temperature exceeds trip_temp, the fan
* gets turned on.
* * In case the fan is running, temperature must fall below
* (trip_temp - hyst) so that the fan gets turned off again.
*
*/
static int bang_bang_control(struct thermal_zone_device *tz, int trip)
{
struct thermal_instance *instance;
thermal_zone_trip_update(tz, trip);
mutex_lock(&tz->lock);
list_for_each_entry(instance, &tz->thermal_instances, tz_node)
thermal_cdev_update(instance->cdev);
mutex_unlock(&tz->lock);
return 0;
}
static struct thermal_governor thermal_gov_bang_bang = {
.name = "bang_bang",
.throttle = bang_bang_control,
};
int thermal_gov_bang_bang_register(void)
{
return thermal_register_governor(&thermal_gov_bang_bang);
}
void thermal_gov_bang_bang_unregister(void)
{
thermal_unregister_governor(&thermal_gov_bang_bang);
}