TI ADC128D818 ADC System Monitor With Temperature Sensor
--------------------------------------------------------
Operation modes:
- Mode 0: 7 single-ended voltage readings (IN0-IN6),
1 temperature reading (internal)
- Mode 1: 8 single-ended voltage readings (IN0-IN7),
no temperature
- Mode 2: 4 pseudo-differential voltage readings
(IN0-IN1, IN3-IN2, IN4-IN5, IN7-IN6),
1 temperature reading (internal)
- Mode 3: 4 single-ended voltage readings (IN0-IN3),
2 pseudo-differential voltage readings
(IN4-IN5, IN7-IN6),
1 temperature reading (internal)
If no operation mode is configured via device tree, the driver keeps the
currently active chip operation mode (default is mode 0).
Required node properties:
- compatible: must be set to "ti,adc128d818"
- reg: I2C address of the device
Optional node properties:
- ti,mode: Operation mode (u8) (see above).
Example (operation mode 2):
adc128d818@1d {
compatible = "ti,adc128d818";
reg = <0x1d>;
ti,mode = /bits/ 8 <2>;
};