30 lines
1.3 KiB
Plaintext
30 lines
1.3 KiB
Plaintext
|
What: /sys/bus/iio/devices/triggerX/master_mode_available
|
||
|
KernelVersion: 4.11
|
||
|
Contact: benjamin.gaignard@st.com
|
||
|
Description:
|
||
|
Reading returns the list possible master modes which are:
|
||
|
- "reset" : The UG bit from the TIMx_EGR register is used as trigger output (TRGO).
|
||
|
- "enable" : The Counter Enable signal CNT_EN is used as trigger output.
|
||
|
- "update" : The update event is selected as trigger output.
|
||
|
For instance a master timer can then be used as a prescaler for a slave timer.
|
||
|
- "compare_pulse" : The trigger output send a positive pulse when the CC1IF flag is to be set.
|
||
|
- "OC1REF" : OC1REF signal is used as trigger output.
|
||
|
- "OC2REF" : OC2REF signal is used as trigger output.
|
||
|
- "OC3REF" : OC3REF signal is used as trigger output.
|
||
|
- "OC4REF" : OC4REF signal is used as trigger output.
|
||
|
|
||
|
What: /sys/bus/iio/devices/triggerX/master_mode
|
||
|
KernelVersion: 4.11
|
||
|
Contact: benjamin.gaignard@st.com
|
||
|
Description:
|
||
|
Reading returns the current master modes.
|
||
|
Writing set the master mode
|
||
|
|
||
|
What: /sys/bus/iio/devices/triggerX/sampling_frequency
|
||
|
KernelVersion: 4.11
|
||
|
Contact: benjamin.gaignard@st.com
|
||
|
Description:
|
||
|
Reading returns the current sampling frequency.
|
||
|
Writing an value different of 0 set and start sampling.
|
||
|
Writing 0 stop sampling.
|