OpenCloudOS-Kernel/include/linux/thermal.h

281 lines
8.9 KiB
C
Raw Normal View History

/*
* thermal.h ($Revision: 0 $)
*
* Copyright (C) 2008 Intel Corp
* Copyright (C) 2008 Zhang Rui <rui.zhang@intel.com>
* Copyright (C) 2008 Sujith Thomas <sujith.thomas@intel.com>
*
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
* This program is free software; you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation; version 2 of the License.
*
* This program is distributed in the hope that it will be useful, but
* WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
* General Public License for more details.
*
* You should have received a copy of the GNU General Public License along
* with this program; if not, write to the Free Software Foundation, Inc.,
* 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
*
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
*/
#ifndef __THERMAL_H__
#define __THERMAL_H__
#include <linux/idr.h>
#include <linux/device.h>
#include <linux/workqueue.h>
#define THERMAL_TRIPS_NONE -1
#define THERMAL_MAX_TRIPS 12
#define THERMAL_NAME_LENGTH 20
/* invalid cooling state */
#define THERMAL_CSTATE_INVALID -1UL
/* No upper/lower limit requirement */
#define THERMAL_NO_LIMIT THERMAL_CSTATE_INVALID
/* Unit conversion macros */
#define KELVIN_TO_CELSIUS(t) (long)(((long)t-2732 >= 0) ? \
((long)t-2732+5)/10 : ((long)t-2732-5)/10)
#define CELSIUS_TO_KELVIN(t) ((t)*10+2732)
/* Adding event notification support elements */
#define THERMAL_GENL_FAMILY_NAME "thermal_event"
#define THERMAL_GENL_VERSION 0x01
#define THERMAL_GENL_MCAST_GROUP_NAME "thermal_mc_grp"
/* Default Thermal Governor */
#if defined(CONFIG_THERMAL_DEFAULT_GOV_STEP_WISE)
#define DEFAULT_THERMAL_GOVERNOR "step_wise"
#elif defined(CONFIG_THERMAL_DEFAULT_GOV_FAIR_SHARE)
#define DEFAULT_THERMAL_GOVERNOR "fair_share"
#elif defined(CONFIG_THERMAL_DEFAULT_GOV_USER_SPACE)
#define DEFAULT_THERMAL_GOVERNOR "user_space"
#endif
struct thermal_zone_device;
struct thermal_cooling_device;
enum thermal_device_mode {
THERMAL_DEVICE_DISABLED = 0,
THERMAL_DEVICE_ENABLED,
};
enum thermal_trip_type {
THERMAL_TRIP_ACTIVE = 0,
THERMAL_TRIP_PASSIVE,
THERMAL_TRIP_HOT,
THERMAL_TRIP_CRITICAL,
};
enum thermal_trend {
THERMAL_TREND_STABLE, /* temperature is stable */
THERMAL_TREND_RAISING, /* temperature is raising */
THERMAL_TREND_DROPPING, /* temperature is dropping */
THERMAL_TREND_RAISE_FULL, /* apply highest cooling action */
THERMAL_TREND_DROP_FULL, /* apply lowest cooling action */
};
/* Events supported by Thermal Netlink */
enum events {
THERMAL_AUX0,
THERMAL_AUX1,
THERMAL_CRITICAL,
THERMAL_DEV_FAULT,
};
/* attributes of thermal_genl_family */
enum {
THERMAL_GENL_ATTR_UNSPEC,
THERMAL_GENL_ATTR_EVENT,
__THERMAL_GENL_ATTR_MAX,
};
#define THERMAL_GENL_ATTR_MAX (__THERMAL_GENL_ATTR_MAX - 1)
/* commands supported by the thermal_genl_family */
enum {
THERMAL_GENL_CMD_UNSPEC,
THERMAL_GENL_CMD_EVENT,
__THERMAL_GENL_CMD_MAX,
};
#define THERMAL_GENL_CMD_MAX (__THERMAL_GENL_CMD_MAX - 1)
struct thermal_zone_device_ops {
int (*bind) (struct thermal_zone_device *,
struct thermal_cooling_device *);
int (*unbind) (struct thermal_zone_device *,
struct thermal_cooling_device *);
int (*get_temp) (struct thermal_zone_device *, unsigned long *);
int (*get_mode) (struct thermal_zone_device *,
enum thermal_device_mode *);
int (*set_mode) (struct thermal_zone_device *,
enum thermal_device_mode);
int (*get_trip_type) (struct thermal_zone_device *, int,
enum thermal_trip_type *);
int (*get_trip_temp) (struct thermal_zone_device *, int,
unsigned long *);
int (*set_trip_temp) (struct thermal_zone_device *, int,
unsigned long);
int (*get_trip_hyst) (struct thermal_zone_device *, int,
unsigned long *);
int (*set_trip_hyst) (struct thermal_zone_device *, int,
unsigned long);
int (*get_crit_temp) (struct thermal_zone_device *, unsigned long *);
int (*set_emul_temp) (struct thermal_zone_device *, unsigned long);
int (*get_trend) (struct thermal_zone_device *, int,
enum thermal_trend *);
int (*notify) (struct thermal_zone_device *, int,
enum thermal_trip_type);
};
struct thermal_cooling_device_ops {
int (*get_max_state) (struct thermal_cooling_device *, unsigned long *);
int (*get_cur_state) (struct thermal_cooling_device *, unsigned long *);
int (*set_cur_state) (struct thermal_cooling_device *, unsigned long);
};
struct thermal_cooling_device {
int id;
char type[THERMAL_NAME_LENGTH];
struct device device;
void *devdata;
const struct thermal_cooling_device_ops *ops;
bool updated; /* true if the cooling device does not need update */
struct mutex lock; /* protect thermal_instances list */
struct list_head thermal_instances;
struct list_head node;
};
struct thermal_attr {
struct device_attribute attr;
char name[THERMAL_NAME_LENGTH];
};
struct thermal_zone_device {
int id;
char type[THERMAL_NAME_LENGTH];
struct device device;
struct thermal_attr *trip_temp_attrs;
struct thermal_attr *trip_type_attrs;
struct thermal_attr *trip_hyst_attrs;
void *devdata;
int trips;
int passive_delay;
int polling_delay;
int temperature;
int last_temperature;
int emul_temperature;
int passive;
unsigned int forced_passive;
const struct thermal_zone_device_ops *ops;
const struct thermal_zone_params *tzp;
struct thermal_governor *governor;
struct list_head thermal_instances;
struct idr idr;
struct mutex lock; /* protect thermal_instances list */
struct list_head node;
struct delayed_work poll_queue;
};
/* Structure that holds thermal governor information */
struct thermal_governor {
char name[THERMAL_NAME_LENGTH];
int (*throttle)(struct thermal_zone_device *tz, int trip);
struct list_head governor_list;
};
/* Structure that holds binding parameters for a zone */
struct thermal_bind_params {
struct thermal_cooling_device *cdev;
/*
* This is a measure of 'how effectively these devices can
* cool 'this' thermal zone. The shall be determined by platform
* characterization. This is on a 'percentage' scale.
* See Documentation/thermal/sysfs-api.txt for more information.
*/
int weight;
/*
* This is a bit mask that gives the binding relation between this
* thermal zone and cdev, for a particular trip point.
* See Documentation/thermal/sysfs-api.txt for more information.
*/
int trip_mask;
/*
* This is an array of cooling state limits. Must have exactly
* 2 * thermal_zone.number_of_trip_points. It is an array consisting
* of tuples <lower-state upper-state> of state limits. Each trip
* will be associated with one state limit tuple when binding.
* A NULL pointer means <THERMAL_NO_LIMITS THERMAL_NO_LIMITS>
* on all trips.
*/
unsigned long *binding_limits;
int (*match) (struct thermal_zone_device *tz,
struct thermal_cooling_device *cdev);
};
/* Structure to define Thermal Zone parameters */
struct thermal_zone_params {
char governor_name[THERMAL_NAME_LENGTH];
/*
* a boolean to indicate if the thermal to hwmon sysfs interface
* is required. when no_hwmon == false, a hwmon sysfs interface
* will be created. when no_hwmon == true, nothing will be done
*/
bool no_hwmon;
int num_tbps; /* Number of tbp entries */
struct thermal_bind_params *tbp;
};
struct thermal_genl_event {
u32 orig;
enum events event;
};
/* Function declarations */
struct thermal_zone_device *thermal_zone_device_register(const char *, int, int,
void *, const struct thermal_zone_device_ops *,
const struct thermal_zone_params *, int, int);
void thermal_zone_device_unregister(struct thermal_zone_device *);
int thermal_zone_bind_cooling_device(struct thermal_zone_device *, int,
struct thermal_cooling_device *,
unsigned long, unsigned long);
int thermal_zone_unbind_cooling_device(struct thermal_zone_device *, int,
struct thermal_cooling_device *);
void thermal_zone_device_update(struct thermal_zone_device *);
struct thermal_cooling_device *thermal_cooling_device_register(char *, void *,
const struct thermal_cooling_device_ops *);
void thermal_cooling_device_unregister(struct thermal_cooling_device *);
struct thermal_zone_device *thermal_zone_get_zone_by_name(const char *name);
int thermal_zone_get_temp(struct thermal_zone_device *tz, unsigned long *temp);
int get_tz_trend(struct thermal_zone_device *, int);
struct thermal_instance *get_thermal_instance(struct thermal_zone_device *,
struct thermal_cooling_device *, int);
void thermal_cdev_update(struct thermal_cooling_device *);
void thermal_notify_framework(struct thermal_zone_device *, int);
#ifdef CONFIG_NET
extern int thermal_generate_netlink_event(struct thermal_zone_device *tz,
enum events event);
#else
static inline int thermal_generate_netlink_event(struct thermal_zone_device *tz,
enum events event)
{
return 0;
}
#endif
#endif /* __THERMAL_H__ */