2021-01-18 12:11:56 +08:00
|
|
|
// SPDX-License-Identifier: GPL-2.0
|
|
|
|
/*
|
|
|
|
* Qualcomm SDX55 APCS clock controller driver
|
|
|
|
*
|
|
|
|
* Copyright (c) 2020, Linaro Limited
|
|
|
|
* Author: Manivannan Sadhasivam <manivannan.sadhasivam@linaro.org>
|
|
|
|
*/
|
|
|
|
|
|
|
|
#include <linux/clk.h>
|
|
|
|
#include <linux/clk-provider.h>
|
|
|
|
#include <linux/cpu.h>
|
|
|
|
#include <linux/kernel.h>
|
|
|
|
#include <linux/module.h>
|
|
|
|
#include <linux/platform_device.h>
|
|
|
|
#include <linux/pm_domain.h>
|
|
|
|
#include <linux/regmap.h>
|
|
|
|
#include <linux/slab.h>
|
|
|
|
|
|
|
|
#include "clk-regmap.h"
|
|
|
|
#include "clk-regmap-mux-div.h"
|
|
|
|
|
|
|
|
static const u32 apcs_mux_clk_parent_map[] = { 0, 1, 5 };
|
|
|
|
|
|
|
|
static const struct clk_parent_data pdata[] = {
|
|
|
|
{ .fw_name = "ref" },
|
|
|
|
{ .fw_name = "aux" },
|
|
|
|
{ .fw_name = "pll" },
|
|
|
|
};
|
|
|
|
|
|
|
|
/*
|
|
|
|
* We use the notifier function for switching to a temporary safe configuration
|
|
|
|
* (mux and divider), while the A7 PLL is reconfigured.
|
|
|
|
*/
|
|
|
|
static int a7cc_notifier_cb(struct notifier_block *nb, unsigned long event,
|
|
|
|
void *data)
|
|
|
|
{
|
|
|
|
int ret = 0;
|
|
|
|
struct clk_regmap_mux_div *md = container_of(nb,
|
|
|
|
struct clk_regmap_mux_div,
|
|
|
|
clk_nb);
|
|
|
|
if (event == PRE_RATE_CHANGE)
|
|
|
|
/* set the mux and divider to safe frequency (400mhz) */
|
|
|
|
ret = mux_div_set_src_div(md, 1, 2);
|
|
|
|
|
|
|
|
return notifier_from_errno(ret);
|
|
|
|
}
|
|
|
|
|
|
|
|
static int qcom_apcs_sdx55_clk_probe(struct platform_device *pdev)
|
|
|
|
{
|
|
|
|
struct device *dev = &pdev->dev;
|
|
|
|
struct device *parent = dev->parent;
|
|
|
|
struct device *cpu_dev;
|
|
|
|
struct clk_regmap_mux_div *a7cc;
|
|
|
|
struct regmap *regmap;
|
|
|
|
struct clk_init_data init = { };
|
|
|
|
int ret;
|
|
|
|
|
|
|
|
regmap = dev_get_regmap(parent, NULL);
|
2021-05-11 15:09:08 +08:00
|
|
|
if (!regmap) {
|
|
|
|
dev_err(dev, "Failed to get parent regmap\n");
|
|
|
|
return -ENODEV;
|
|
|
|
}
|
2021-01-18 12:11:56 +08:00
|
|
|
|
|
|
|
a7cc = devm_kzalloc(dev, sizeof(*a7cc), GFP_KERNEL);
|
|
|
|
if (!a7cc)
|
|
|
|
return -ENOMEM;
|
|
|
|
|
|
|
|
init.name = "a7mux";
|
|
|
|
init.parent_data = pdata;
|
|
|
|
init.num_parents = ARRAY_SIZE(pdata);
|
|
|
|
init.ops = &clk_regmap_mux_div_ops;
|
|
|
|
|
|
|
|
a7cc->clkr.hw.init = &init;
|
|
|
|
a7cc->clkr.regmap = regmap;
|
|
|
|
a7cc->reg_offset = 0x8;
|
|
|
|
a7cc->hid_width = 5;
|
|
|
|
a7cc->hid_shift = 0;
|
|
|
|
a7cc->src_width = 3;
|
|
|
|
a7cc->src_shift = 8;
|
|
|
|
a7cc->parent_map = apcs_mux_clk_parent_map;
|
|
|
|
|
|
|
|
a7cc->pclk = devm_clk_get(parent, "pll");
|
2021-04-28 00:45:22 +08:00
|
|
|
if (IS_ERR(a7cc->pclk))
|
|
|
|
return dev_err_probe(dev, PTR_ERR(a7cc->pclk),
|
|
|
|
"Failed to get PLL clk\n");
|
2021-01-18 12:11:56 +08:00
|
|
|
|
|
|
|
a7cc->clk_nb.notifier_call = a7cc_notifier_cb;
|
|
|
|
ret = clk_notifier_register(a7cc->pclk, &a7cc->clk_nb);
|
2021-04-28 00:45:22 +08:00
|
|
|
if (ret)
|
|
|
|
return dev_err_probe(dev, ret,
|
|
|
|
"Failed to register clock notifier\n");
|
2021-01-18 12:11:56 +08:00
|
|
|
|
|
|
|
ret = devm_clk_register_regmap(dev, &a7cc->clkr);
|
|
|
|
if (ret) {
|
|
|
|
dev_err_probe(dev, ret, "Failed to register regmap clock\n");
|
|
|
|
goto err;
|
|
|
|
}
|
|
|
|
|
|
|
|
ret = devm_of_clk_add_hw_provider(dev, of_clk_hw_simple_get,
|
|
|
|
&a7cc->clkr.hw);
|
|
|
|
if (ret) {
|
|
|
|
dev_err_probe(dev, ret, "Failed to add clock provider\n");
|
|
|
|
goto err;
|
|
|
|
}
|
|
|
|
|
|
|
|
platform_set_drvdata(pdev, a7cc);
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Attach the power domain to cpudev. Since there is no dedicated driver
|
|
|
|
* for CPUs and the SDX55 platform lacks hardware specific CPUFreq
|
|
|
|
* driver, there seems to be no better place to do this. So do it here!
|
|
|
|
*/
|
|
|
|
cpu_dev = get_cpu_device(0);
|
|
|
|
dev_pm_domain_attach(cpu_dev, true);
|
|
|
|
|
|
|
|
return 0;
|
|
|
|
|
|
|
|
err:
|
|
|
|
clk_notifier_unregister(a7cc->pclk, &a7cc->clk_nb);
|
|
|
|
return ret;
|
|
|
|
}
|
|
|
|
|
2023-03-13 00:15:04 +08:00
|
|
|
static void qcom_apcs_sdx55_clk_remove(struct platform_device *pdev)
|
2021-01-18 12:11:56 +08:00
|
|
|
{
|
|
|
|
struct device *cpu_dev = get_cpu_device(0);
|
|
|
|
struct clk_regmap_mux_div *a7cc = platform_get_drvdata(pdev);
|
|
|
|
|
|
|
|
clk_notifier_unregister(a7cc->pclk, &a7cc->clk_nb);
|
|
|
|
dev_pm_domain_detach(cpu_dev, true);
|
|
|
|
}
|
|
|
|
|
|
|
|
static struct platform_driver qcom_apcs_sdx55_clk_driver = {
|
|
|
|
.probe = qcom_apcs_sdx55_clk_probe,
|
2023-03-13 00:15:04 +08:00
|
|
|
.remove_new = qcom_apcs_sdx55_clk_remove,
|
2021-01-18 12:11:56 +08:00
|
|
|
.driver = {
|
|
|
|
.name = "qcom-sdx55-acps-clk",
|
|
|
|
},
|
|
|
|
};
|
|
|
|
module_platform_driver(qcom_apcs_sdx55_clk_driver);
|
|
|
|
|
|
|
|
MODULE_AUTHOR("Manivannan Sadhasivam <manivannan.sadhasivam@linaro.org>");
|
|
|
|
MODULE_LICENSE("GPL v2");
|
|
|
|
MODULE_DESCRIPTION("Qualcomm SDX55 APCS clock driver");
|