* Read-Copy Update mechanism for mutual exclusion
*
* This program is free software; you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation; either version 2 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program; if not, write to the Free Software
* Foundation, Inc., 59 Temple Place - Suite 330, Boston, MA 02111-1307, USA.
*
* Copyright IBM Corporation, 2001
*
* Authors: Dipankar Sarma <dipankar@in.ibm.com>
* Manfred Spraul <manfred@colorfullife.com>
*
* Based on the original work by Paul McKenney <paulmck@us.ibm.com>
* and inputs from Rusty Russell, Andrea Arcangeli and Andi Kleen.
* Papers:
* http://www.rdrop.com/users/paulmck/paper/rclockpdcsproof.pdf
* http://lse.sourceforge.net/locking/rclock_OLS.2001.05.01c.sc.pdf (OLS2001)
*
* For detailed explanation of Read-Copy Update mechanism see -
* http://lse.sourceforge.net/locking/rcupdate.html
*
*/
#include <linux/types.h>
#include <linux/kernel.h>
#include <linux/init.h>
#include <linux/spinlock.h>
#include <linux/smp.h>
#include <linux/interrupt.h>
#include <linux/sched.h>
#include <linux/atomic.h>
#include <linux/bitops.h>
#include <linux/percpu.h>
#include <linux/notifier.h>
#include <linux/cpu.h>
#include <linux/mutex.h>
#include <linux/export.h>
#include <linux/hardirq.h>
#include <linux/delay.h>
#define CREATE_TRACE_POINTS
#include <trace/events/rcu.h>
#include "rcu.h"
#ifdef CONFIG_PREEMPT_RCU
/*
* Preemptible RCU implementation for rcu_read_lock().
* Just increment ->rcu_read_lock_nesting, shared state will be updated
* if we block.
*/
void __rcu_read_lock(void)
{
current->rcu_read_lock_nesting++;
barrier(); /* critical section after entry code. */
}
EXPORT_SYMBOL_GPL(__rcu_read_lock);
/*
* Preemptible RCU implementation for rcu_read_unlock().
* Decrement ->rcu_read_lock_nesting. If the result is zero (outermost
* rcu_read_unlock()) and ->rcu_read_unlock_special is non-zero, then
* invoke rcu_read_unlock_special() to clean up after a context switch
* in an RCU read-side critical section and other special cases.
*/
void __rcu_read_unlock(void)
{
struct task_struct *t = current;
if (t->rcu_read_lock_nesting != 1) {
--t->rcu_read_lock_nesting;
} else {
barrier(); /* critical section before exit code. */
t->rcu_read_lock_nesting = INT_MIN;
#ifdef CONFIG_PROVE_RCU_DELAY
udelay(10); /* Make preemption more probable. */
#endif /* #ifdef CONFIG_PROVE_RCU_DELAY */
barrier(); /* assign before ->rcu_read_unlock_special load */
if (unlikely(ACCESS_ONCE(t->rcu_read_unlock_special)))
rcu_read_unlock_special(t);
barrier(); /* ->rcu_read_unlock_special load before assign */
t->rcu_read_lock_nesting = 0;
}
#ifdef CONFIG_PROVE_LOCKING
{
int rrln = ACCESS_ONCE(t->rcu_read_lock_nesting);
WARN_ON_ONCE(rrln < 0 && rrln > INT_MIN / 2);
}
#endif /* #ifdef CONFIG_PROVE_LOCKING */
}
EXPORT_SYMBOL_GPL(__rcu_read_unlock);
/*
* Check for a task exiting while in a preemptible-RCU read-side
* critical section, clean up if so. No need to issue warnings,
* as debug_check_no_locks_held() already does this if lockdep
* is enabled.
*/
void exit_rcu(void)
{
struct task_struct *t = current;
if (likely(list_empty(&current->rcu_node_entry)))
return;
t->rcu_read_lock_nesting = 1;
barrier();
t->rcu_read_unlock_special = RCU_READ_UNLOCK_BLOCKED;
__rcu_read_unlock();
}
#else /* #ifdef CONFIG_PREEMPT_RCU */
void exit_rcu(void)
{
}
#endif /* #else #ifdef CONFIG_PREEMPT_RCU */
#ifdef CONFIG_DEBUG_LOCK_ALLOC
static struct lock_class_key rcu_lock_key;
struct lockdep_map rcu_lock_map =
STATIC_LOCKDEP_MAP_INIT("rcu_read_lock", &rcu_lock_key);
EXPORT_SYMBOL_GPL(rcu_lock_map);
rcu: Introduce lockdep-based checking to RCU read-side primitives Inspection is proving insufficient to catch all RCU misuses, which is understandable given that rcu_dereference() might be protected by any of four different flavors of RCU (RCU, RCU-bh, RCU-sched, and SRCU), and might also/instead be protected by any of a number of locking primitives. It is therefore time to enlist the aid of lockdep. This set of patches is inspired by earlier work by Peter Zijlstra and Thomas Gleixner, and takes the following approach: o Set up separate lockdep classes for RCU, RCU-bh, and RCU-sched. o Set up separate lockdep classes for each instance of SRCU. o Create primitives that check for being in an RCU read-side critical section. These return exact answers if lockdep is fully enabled, but if unsure, report being in an RCU read-side critical section. (We want to avoid false positives!) The primitives are: For RCU: rcu_read_lock_held(void) For RCU-bh: rcu_read_lock_bh_held(void) For RCU-sched: rcu_read_lock_sched_held(void) For SRCU: srcu_read_lock_held(struct srcu_struct *sp) o Add rcu_dereference_check(), which takes a second argument in which one places a boolean expression based on the above primitives and/or lockdep_is_held(). o A new kernel configuration parameter, CONFIG_PROVE_RCU, enables rcu_dereference_check(). This depends on CONFIG_PROVE_LOCKING, and should be quite helpful during the transition period while CONFIG_PROVE_RCU-unaware patches are in flight. The existing rcu_dereference() primitive does no checking, but upcoming patches will change that. Signed-off-by: Paul E. McKenney <paulmck@linux.vnet.ibm.com> Cc: laijs@cn.fujitsu.com Cc: dipankar@in.ibm.com Cc: mathieu.desnoyers@polymtl.ca Cc: josh@joshtriplett.org Cc: dvhltc@us.ibm.com Cc: niv@us.ibm.com Cc: peterz@infradead.org Cc: rostedt@goodmis.org Cc: Valdis.Kletnieks@vt.edu Cc: dhowells@redhat.com LKML-Reference: <1266887105-1528-1-git-send-email-paulmck@linux.vnet.ibm.com> Signed-off-by: Ingo Molnar <mingo@elte.hu>
2010-02-23 09:04:45 +08:00
static struct lock_class_key rcu_bh_lock_key;
struct lockdep_map rcu_bh_lock_map =
STATIC_LOCKDEP_MAP_INIT("rcu_read_lock_bh", &rcu_bh_lock_key);
EXPORT_SYMBOL_GPL(rcu_bh_lock_map);
static struct lock_class_key rcu_sched_lock_key;
struct lockdep_map rcu_sched_lock_map =
STATIC_LOCKDEP_MAP_INIT("rcu_read_lock_sched", &rcu_sched_lock_key);
EXPORT_SYMBOL_GPL(rcu_sched_lock_map);
#endif
#ifdef CONFIG_DEBUG_LOCK_ALLOC
int debug_lockdep_rcu_enabled(void)
{
return rcu_scheduler_active && debug_locks &&
current->lockdep_recursion == 0;
}
EXPORT_SYMBOL_GPL(debug_lockdep_rcu_enabled);
/**
* rcu_read_lock_bh_held() - might we be in RCU-bh read-side critical section?
*
* Check for bottom half being disabled, which covers both the
* CONFIG_PROVE_RCU and not cases. Note that if someone uses
* rcu_read_lock_bh(), but then later enables BH, lockdep (if enabled)
* will show the situation. This is useful for debug checks in functions
* that require that they be called within an RCU read-side critical
* section.
*
* Check debug_lockdep_rcu_enabled() to prevent false positives during boot.
*
* Note that rcu_read_lock() is disallowed if the CPU is either idle or
* offline from an RCU perspective, so check for those as well.
*/
int rcu_read_lock_bh_held(void)
{
if (!debug_lockdep_rcu_enabled())
return 1;
if (rcu_is_cpu_idle())
return 0;
if (!rcu_lockdep_current_cpu_online())
return 0;
return in_softirq() || irqs_disabled();
}
EXPORT_SYMBOL_GPL(rcu_read_lock_bh_held);
#endif /* #ifdef CONFIG_DEBUG_LOCK_ALLOC */
struct rcu_synchronize {
struct rcu_head head;
struct completion completion;
};
/*
* Awaken the corresponding synchronize_rcu() instance now that a
* grace period has elapsed.
*/
static void wakeme_after_rcu(struct rcu_head *head)
{
struct rcu_synchronize *rcu;
rcu = container_of(head, struct rcu_synchronize, head);
complete(&rcu->completion);
}
void wait_rcu_gp(call_rcu_func_t crf)
{
struct rcu_synchronize rcu;
init_rcu_head_on_stack(&rcu.head);
init_completion(&rcu.completion);
/* Will wake me after RCU finished. */
crf(&rcu.head, wakeme_after_rcu);
/* Wait for it. */
wait_for_completion(&rcu.completion);
destroy_rcu_head_on_stack(&rcu.head);
}
EXPORT_SYMBOL_GPL(wait_rcu_gp);
#ifdef CONFIG_PROVE_RCU
/*
* wrapper function to avoid #include problems.
*/
int rcu_my_thread_group_empty(void)
{
return thread_group_empty(current);
}
EXPORT_SYMBOL_GPL(rcu_my_thread_group_empty);
#endif /* #ifdef CONFIG_PROVE_RCU */
tree/tiny rcu: Add debug RCU head objects Helps finding racy users of call_rcu(), which results in hangs because list entries are overwritten and/or skipped. Changelog since v4: - Bissectability is now OK - Now generate a WARN_ON_ONCE() for non-initialized rcu_head passed to call_rcu(). Statically initialized objects are detected with object_is_static(). - Rename rcu_head_init_on_stack to init_rcu_head_on_stack. - Remove init_rcu_head() completely. Changelog since v3: - Include comments from Lai Jiangshan This new patch version is based on the debugobjects with the newly introduced "active state" tracker. Non-initialized entries are all considered as "statically initialized". An activation fixup (triggered by call_rcu()) takes care of performing the debug object initialization without issuing any warning. Since we cannot increase the size of struct rcu_head, I don't see much room to put an identifier for statically initialized rcu_head structures. So for now, we have to live without "activation without explicit init" detection. But the main purpose of this debug option is to detect double-activations (double call_rcu() use of a rcu_head before the callback is executed), which is correctly addressed here. This also detects potential internal RCU callback corruption, which would cause the callbacks to be executed twice. Signed-off-by: Mathieu Desnoyers <mathieu.desnoyers@efficios.com> CC: David S. Miller <davem@davemloft.net> CC: "Paul E. McKenney" <paulmck@linux.vnet.ibm.com> CC: akpm@linux-foundation.org CC: mingo@elte.hu CC: laijs@cn.fujitsu.com CC: dipankar@in.ibm.com CC: josh@joshtriplett.org CC: dvhltc@us.ibm.com CC: niv@us.ibm.com CC: tglx@linutronix.de CC: peterz@infradead.org CC: rostedt@goodmis.org CC: Valdis.Kletnieks@vt.edu CC: dhowells@redhat.com CC: eric.dumazet@gmail.com CC: Alexey Dobriyan <adobriyan@gmail.com> Signed-off-by: Paul E. McKenney <paulmck@linux.vnet.ibm.com> Reviewed-by: Lai Jiangshan <laijs@cn.fujitsu.com>
2010-04-17 20:48:42 +08:00
#ifdef CONFIG_DEBUG_OBJECTS_RCU_HEAD
static inline void debug_init_rcu_head(struct rcu_head *head)
{
debug_object_init(head, &rcuhead_debug_descr);
}
static inline void debug_rcu_head_free(struct rcu_head *head)
{
debug_object_free(head, &rcuhead_debug_descr);
}
/*
* fixup_init is called when:
* - an active object is initialized
*/
static int rcuhead_fixup_init(void *addr, enum debug_obj_state state)
{
struct rcu_head *head = addr;
switch (state) {
case ODEBUG_STATE_ACTIVE:
/*
* Ensure that queued callbacks are all executed.
* If we detect that we are nested in a RCU read-side critical
* section, we should simply fail, otherwise we would deadlock.
* In !PREEMPT configurations, there is no way to tell if we are
* in a RCU read-side critical section or not, so we never
* attempt any fixup and just print a warning.
tree/tiny rcu: Add debug RCU head objects Helps finding racy users of call_rcu(), which results in hangs because list entries are overwritten and/or skipped. Changelog since v4: - Bissectability is now OK - Now generate a WARN_ON_ONCE() for non-initialized rcu_head passed to call_rcu(). Statically initialized objects are detected with object_is_static(). - Rename rcu_head_init_on_stack to init_rcu_head_on_stack. - Remove init_rcu_head() completely. Changelog since v3: - Include comments from Lai Jiangshan This new patch version is based on the debugobjects with the newly introduced "active state" tracker. Non-initialized entries are all considered as "statically initialized". An activation fixup (triggered by call_rcu()) takes care of performing the debug object initialization without issuing any warning. Since we cannot increase the size of struct rcu_head, I don't see much room to put an identifier for statically initialized rcu_head structures. So for now, we have to live without "activation without explicit init" detection. But the main purpose of this debug option is to detect double-activations (double call_rcu() use of a rcu_head before the callback is executed), which is correctly addressed here. This also detects potential internal RCU callback corruption, which would cause the callbacks to be executed twice. Signed-off-by: Mathieu Desnoyers <mathieu.desnoyers@efficios.com> CC: David S. Miller <davem@davemloft.net> CC: "Paul E. McKenney" <paulmck@linux.vnet.ibm.com> CC: akpm@linux-foundation.org CC: mingo@elte.hu CC: laijs@cn.fujitsu.com CC: dipankar@in.ibm.com CC: josh@joshtriplett.org CC: dvhltc@us.ibm.com CC: niv@us.ibm.com CC: tglx@linutronix.de CC: peterz@infradead.org CC: rostedt@goodmis.org CC: Valdis.Kletnieks@vt.edu CC: dhowells@redhat.com CC: eric.dumazet@gmail.com CC: Alexey Dobriyan <adobriyan@gmail.com> Signed-off-by: Paul E. McKenney <paulmck@linux.vnet.ibm.com> Reviewed-by: Lai Jiangshan <laijs@cn.fujitsu.com>
2010-04-17 20:48:42 +08:00
*/
#ifndef CONFIG_PREEMPT
WARN_ON_ONCE(1);
return 0;
#endif
tree/tiny rcu: Add debug RCU head objects Helps finding racy users of call_rcu(), which results in hangs because list entries are overwritten and/or skipped. Changelog since v4: - Bissectability is now OK - Now generate a WARN_ON_ONCE() for non-initialized rcu_head passed to call_rcu(). Statically initialized objects are detected with object_is_static(). - Rename rcu_head_init_on_stack to init_rcu_head_on_stack. - Remove init_rcu_head() completely. Changelog since v3: - Include comments from Lai Jiangshan This new patch version is based on the debugobjects with the newly introduced "active state" tracker. Non-initialized entries are all considered as "statically initialized". An activation fixup (triggered by call_rcu()) takes care of performing the debug object initialization without issuing any warning. Since we cannot increase the size of struct rcu_head, I don't see much room to put an identifier for statically initialized rcu_head structures. So for now, we have to live without "activation without explicit init" detection. But the main purpose of this debug option is to detect double-activations (double call_rcu() use of a rcu_head before the callback is executed), which is correctly addressed here. This also detects potential internal RCU callback corruption, which would cause the callbacks to be executed twice. Signed-off-by: Mathieu Desnoyers <mathieu.desnoyers@efficios.com> CC: David S. Miller <davem@davemloft.net> CC: "Paul E. McKenney" <paulmck@linux.vnet.ibm.com> CC: akpm@linux-foundation.org CC: mingo@elte.hu CC: laijs@cn.fujitsu.com CC: dipankar@in.ibm.com CC: josh@joshtriplett.org CC: dvhltc@us.ibm.com CC: niv@us.ibm.com CC: tglx@linutronix.de CC: peterz@infradead.org CC: rostedt@goodmis.org CC: Valdis.Kletnieks@vt.edu CC: dhowells@redhat.com CC: eric.dumazet@gmail.com CC: Alexey Dobriyan <adobriyan@gmail.com> Signed-off-by: Paul E. McKenney <paulmck@linux.vnet.ibm.com> Reviewed-by: Lai Jiangshan <laijs@cn.fujitsu.com>
2010-04-17 20:48:42 +08:00
if (rcu_preempt_depth() != 0 || preempt_count() != 0 ||
irqs_disabled()) {
WARN_ON_ONCE(1);
tree/tiny rcu: Add debug RCU head objects Helps finding racy users of call_rcu(), which results in hangs because list entries are overwritten and/or skipped. Changelog since v4: - Bissectability is now OK - Now generate a WARN_ON_ONCE() for non-initialized rcu_head passed to call_rcu(). Statically initialized objects are detected with object_is_static(). - Rename rcu_head_init_on_stack to init_rcu_head_on_stack. - Remove init_rcu_head() completely. Changelog since v3: - Include comments from Lai Jiangshan This new patch version is based on the debugobjects with the newly introduced "active state" tracker. Non-initialized entries are all considered as "statically initialized". An activation fixup (triggered by call_rcu()) takes care of performing the debug object initialization without issuing any warning. Since we cannot increase the size of struct rcu_head, I don't see much room to put an identifier for statically initialized rcu_head structures. So for now, we have to live without "activation without explicit init" detection. But the main purpose of this debug option is to detect double-activations (double call_rcu() use of a rcu_head before the callback is executed), which is correctly addressed here. This also detects potential internal RCU callback corruption, which would cause the callbacks to be executed twice. Signed-off-by: Mathieu Desnoyers <mathieu.desnoyers@efficios.com> CC: David S. Miller <davem@davemloft.net> CC: "Paul E. McKenney" <paulmck@linux.vnet.ibm.com> CC: akpm@linux-foundation.org CC: mingo@elte.hu CC: laijs@cn.fujitsu.com CC: dipankar@in.ibm.com CC: josh@joshtriplett.org CC: dvhltc@us.ibm.com CC: niv@us.ibm.com CC: tglx@linutronix.de CC: peterz@infradead.org CC: rostedt@goodmis.org CC: Valdis.Kletnieks@vt.edu CC: dhowells@redhat.com CC: eric.dumazet@gmail.com CC: Alexey Dobriyan <adobriyan@gmail.com> Signed-off-by: Paul E. McKenney <paulmck@linux.vnet.ibm.com> Reviewed-by: Lai Jiangshan <laijs@cn.fujitsu.com>
2010-04-17 20:48:42 +08:00
return 0;
}
rcu_barrier();
rcu_barrier_sched();
rcu_barrier_bh();
debug_object_init(head, &rcuhead_debug_descr);
return 1;
default:
return 0;
}
}
/*
* fixup_activate is called when:
* - an active object is activated
* - an unknown object is activated (might be a statically initialized object)
* Activation is performed internally by call_rcu().
*/
static int rcuhead_fixup_activate(void *addr, enum debug_obj_state state)
{
struct rcu_head *head = addr;
switch (state) {
case ODEBUG_STATE_NOTAVAILABLE:
/*
* This is not really a fixup. We just make sure that it is
* tracked in the object tracker.
*/
debug_object_init(head, &rcuhead_debug_descr);
debug_object_activate(head, &rcuhead_debug_descr);
return 0;
case ODEBUG_STATE_ACTIVE:
/*
* Ensure that queued callbacks are all executed.
* If we detect that we are nested in a RCU read-side critical
* section, we should simply fail, otherwise we would deadlock.
* In !PREEMPT configurations, there is no way to tell if we are
* in a RCU read-side critical section or not, so we never
* attempt any fixup and just print a warning.
tree/tiny rcu: Add debug RCU head objects Helps finding racy users of call_rcu(), which results in hangs because list entries are overwritten and/or skipped. Changelog since v4: - Bissectability is now OK - Now generate a WARN_ON_ONCE() for non-initialized rcu_head passed to call_rcu(). Statically initialized objects are detected with object_is_static(). - Rename rcu_head_init_on_stack to init_rcu_head_on_stack. - Remove init_rcu_head() completely. Changelog since v3: - Include comments from Lai Jiangshan This new patch version is based on the debugobjects with the newly introduced "active state" tracker. Non-initialized entries are all considered as "statically initialized". An activation fixup (triggered by call_rcu()) takes care of performing the debug object initialization without issuing any warning. Since we cannot increase the size of struct rcu_head, I don't see much room to put an identifier for statically initialized rcu_head structures. So for now, we have to live without "activation without explicit init" detection. But the main purpose of this debug option is to detect double-activations (double call_rcu() use of a rcu_head before the callback is executed), which is correctly addressed here. This also detects potential internal RCU callback corruption, which would cause the callbacks to be executed twice. Signed-off-by: Mathieu Desnoyers <mathieu.desnoyers@efficios.com> CC: David S. Miller <davem@davemloft.net> CC: "Paul E. McKenney" <paulmck@linux.vnet.ibm.com> CC: akpm@linux-foundation.org CC: mingo@elte.hu CC: laijs@cn.fujitsu.com CC: dipankar@in.ibm.com CC: josh@joshtriplett.org CC: dvhltc@us.ibm.com CC: niv@us.ibm.com CC: tglx@linutronix.de CC: peterz@infradead.org CC: rostedt@goodmis.org CC: Valdis.Kletnieks@vt.edu CC: dhowells@redhat.com CC: eric.dumazet@gmail.com CC: Alexey Dobriyan <adobriyan@gmail.com> Signed-off-by: Paul E. McKenney <paulmck@linux.vnet.ibm.com> Reviewed-by: Lai Jiangshan <laijs@cn.fujitsu.com>
2010-04-17 20:48:42 +08:00
*/
#ifndef CONFIG_PREEMPT
WARN_ON_ONCE(1);
return 0;
#endif
tree/tiny rcu: Add debug RCU head objects Helps finding racy users of call_rcu(), which results in hangs because list entries are overwritten and/or skipped. Changelog since v4: - Bissectability is now OK - Now generate a WARN_ON_ONCE() for non-initialized rcu_head passed to call_rcu(). Statically initialized objects are detected with object_is_static(). - Rename rcu_head_init_on_stack to init_rcu_head_on_stack. - Remove init_rcu_head() completely. Changelog since v3: - Include comments from Lai Jiangshan This new patch version is based on the debugobjects with the newly introduced "active state" tracker. Non-initialized entries are all considered as "statically initialized". An activation fixup (triggered by call_rcu()) takes care of performing the debug object initialization without issuing any warning. Since we cannot increase the size of struct rcu_head, I don't see much room to put an identifier for statically initialized rcu_head structures. So for now, we have to live without "activation without explicit init" detection. But the main purpose of this debug option is to detect double-activations (double call_rcu() use of a rcu_head before the callback is executed), which is correctly addressed here. This also detects potential internal RCU callback corruption, which would cause the callbacks to be executed twice. Signed-off-by: Mathieu Desnoyers <mathieu.desnoyers@efficios.com> CC: David S. Miller <davem@davemloft.net> CC: "Paul E. McKenney" <paulmck@linux.vnet.ibm.com> CC: akpm@linux-foundation.org CC: mingo@elte.hu CC: laijs@cn.fujitsu.com CC: dipankar@in.ibm.com CC: josh@joshtriplett.org CC: dvhltc@us.ibm.com CC: niv@us.ibm.com CC: tglx@linutronix.de CC: peterz@infradead.org CC: rostedt@goodmis.org CC: Valdis.Kletnieks@vt.edu CC: dhowells@redhat.com CC: eric.dumazet@gmail.com CC: Alexey Dobriyan <adobriyan@gmail.com> Signed-off-by: Paul E. McKenney <paulmck@linux.vnet.ibm.com> Reviewed-by: Lai Jiangshan <laijs@cn.fujitsu.com>
2010-04-17 20:48:42 +08:00
if (rcu_preempt_depth() != 0 || preempt_count() != 0 ||
irqs_disabled()) {
WARN_ON_ONCE(1);
tree/tiny rcu: Add debug RCU head objects Helps finding racy users of call_rcu(), which results in hangs because list entries are overwritten and/or skipped. Changelog since v4: - Bissectability is now OK - Now generate a WARN_ON_ONCE() for non-initialized rcu_head passed to call_rcu(). Statically initialized objects are detected with object_is_static(). - Rename rcu_head_init_on_stack to init_rcu_head_on_stack. - Remove init_rcu_head() completely. Changelog since v3: - Include comments from Lai Jiangshan This new patch version is based on the debugobjects with the newly introduced "active state" tracker. Non-initialized entries are all considered as "statically initialized". An activation fixup (triggered by call_rcu()) takes care of performing the debug object initialization without issuing any warning. Since we cannot increase the size of struct rcu_head, I don't see much room to put an identifier for statically initialized rcu_head structures. So for now, we have to live without "activation without explicit init" detection. But the main purpose of this debug option is to detect double-activations (double call_rcu() use of a rcu_head before the callback is executed), which is correctly addressed here. This also detects potential internal RCU callback corruption, which would cause the callbacks to be executed twice. Signed-off-by: Mathieu Desnoyers <mathieu.desnoyers@efficios.com> CC: David S. Miller <davem@davemloft.net> CC: "Paul E. McKenney" <paulmck@linux.vnet.ibm.com> CC: akpm@linux-foundation.org CC: mingo@elte.hu CC: laijs@cn.fujitsu.com CC: dipankar@in.ibm.com CC: josh@joshtriplett.org CC: dvhltc@us.ibm.com CC: niv@us.ibm.com CC: tglx@linutronix.de CC: peterz@infradead.org CC: rostedt@goodmis.org CC: Valdis.Kletnieks@vt.edu CC: dhowells@redhat.com CC: eric.dumazet@gmail.com CC: Alexey Dobriyan <adobriyan@gmail.com> Signed-off-by: Paul E. McKenney <paulmck@linux.vnet.ibm.com> Reviewed-by: Lai Jiangshan <laijs@cn.fujitsu.com>
2010-04-17 20:48:42 +08:00
return 0;
}
rcu_barrier();
rcu_barrier_sched();
rcu_barrier_bh();
debug_object_activate(head, &rcuhead_debug_descr);
return 1;
default:
return 0;
}
}
/*
* fixup_free is called when:
* - an active object is freed
*/
static int rcuhead_fixup_free(void *addr, enum debug_obj_state state)
{
struct rcu_head *head = addr;
switch (state) {
case ODEBUG_STATE_ACTIVE:
/*
* Ensure that queued callbacks are all executed.
* If we detect that we are nested in a RCU read-side critical
* section, we should simply fail, otherwise we would deadlock.
* In !PREEMPT configurations, there is no way to tell if we are
* in a RCU read-side critical section or not, so we never
* attempt any fixup and just print a warning.
tree/tiny rcu: Add debug RCU head objects Helps finding racy users of call_rcu(), which results in hangs because list entries are overwritten and/or skipped. Changelog since v4: - Bissectability is now OK - Now generate a WARN_ON_ONCE() for non-initialized rcu_head passed to call_rcu(). Statically initialized objects are detected with object_is_static(). - Rename rcu_head_init_on_stack to init_rcu_head_on_stack. - Remove init_rcu_head() completely. Changelog since v3: - Include comments from Lai Jiangshan This new patch version is based on the debugobjects with the newly introduced "active state" tracker. Non-initialized entries are all considered as "statically initialized". An activation fixup (triggered by call_rcu()) takes care of performing the debug object initialization without issuing any warning. Since we cannot increase the size of struct rcu_head, I don't see much room to put an identifier for statically initialized rcu_head structures. So for now, we have to live without "activation without explicit init" detection. But the main purpose of this debug option is to detect double-activations (double call_rcu() use of a rcu_head before the callback is executed), which is correctly addressed here. This also detects potential internal RCU callback corruption, which would cause the callbacks to be executed twice. Signed-off-by: Mathieu Desnoyers <mathieu.desnoyers@efficios.com> CC: David S. Miller <davem@davemloft.net> CC: "Paul E. McKenney" <paulmck@linux.vnet.ibm.com> CC: akpm@linux-foundation.org CC: mingo@elte.hu CC: laijs@cn.fujitsu.com CC: dipankar@in.ibm.com CC: josh@joshtriplett.org CC: dvhltc@us.ibm.com CC: niv@us.ibm.com CC: tglx@linutronix.de CC: peterz@infradead.org CC: rostedt@goodmis.org CC: Valdis.Kletnieks@vt.edu CC: dhowells@redhat.com CC: eric.dumazet@gmail.com CC: Alexey Dobriyan <adobriyan@gmail.com> Signed-off-by: Paul E. McKenney <paulmck@linux.vnet.ibm.com> Reviewed-by: Lai Jiangshan <laijs@cn.fujitsu.com>
2010-04-17 20:48:42 +08:00
*/
#ifndef CONFIG_PREEMPT
WARN_ON_ONCE(1);
return 0;
#endif
tree/tiny rcu: Add debug RCU head objects Helps finding racy users of call_rcu(), which results in hangs because list entries are overwritten and/or skipped. Changelog since v4: - Bissectability is now OK - Now generate a WARN_ON_ONCE() for non-initialized rcu_head passed to call_rcu(). Statically initialized objects are detected with object_is_static(). - Rename rcu_head_init_on_stack to init_rcu_head_on_stack. - Remove init_rcu_head() completely. Changelog since v3: - Include comments from Lai Jiangshan This new patch version is based on the debugobjects with the newly introduced "active state" tracker. Non-initialized entries are all considered as "statically initialized". An activation fixup (triggered by call_rcu()) takes care of performing the debug object initialization without issuing any warning. Since we cannot increase the size of struct rcu_head, I don't see much room to put an identifier for statically initialized rcu_head structures. So for now, we have to live without "activation without explicit init" detection. But the main purpose of this debug option is to detect double-activations (double call_rcu() use of a rcu_head before the callback is executed), which is correctly addressed here. This also detects potential internal RCU callback corruption, which would cause the callbacks to be executed twice. Signed-off-by: Mathieu Desnoyers <mathieu.desnoyers@efficios.com> CC: David S. Miller <davem@davemloft.net> CC: "Paul E. McKenney" <paulmck@linux.vnet.ibm.com> CC: akpm@linux-foundation.org CC: mingo@elte.hu CC: laijs@cn.fujitsu.com CC: dipankar@in.ibm.com CC: josh@joshtriplett.org CC: dvhltc@us.ibm.com CC: niv@us.ibm.com CC: tglx@linutronix.de CC: peterz@infradead.org CC: rostedt@goodmis.org CC: Valdis.Kletnieks@vt.edu CC: dhowells@redhat.com CC: eric.dumazet@gmail.com CC: Alexey Dobriyan <adobriyan@gmail.com> Signed-off-by: Paul E. McKenney <paulmck@linux.vnet.ibm.com> Reviewed-by: Lai Jiangshan <laijs@cn.fujitsu.com>
2010-04-17 20:48:42 +08:00
if (rcu_preempt_depth() != 0 || preempt_count() != 0 ||
irqs_disabled()) {
WARN_ON_ONCE(1);
tree/tiny rcu: Add debug RCU head objects Helps finding racy users of call_rcu(), which results in hangs because list entries are overwritten and/or skipped. Changelog since v4: - Bissectability is now OK - Now generate a WARN_ON_ONCE() for non-initialized rcu_head passed to call_rcu(). Statically initialized objects are detected with object_is_static(). - Rename rcu_head_init_on_stack to init_rcu_head_on_stack. - Remove init_rcu_head() completely. Changelog since v3: - Include comments from Lai Jiangshan This new patch version is based on the debugobjects with the newly introduced "active state" tracker. Non-initialized entries are all considered as "statically initialized". An activation fixup (triggered by call_rcu()) takes care of performing the debug object initialization without issuing any warning. Since we cannot increase the size of struct rcu_head, I don't see much room to put an identifier for statically initialized rcu_head structures. So for now, we have to live without "activation without explicit init" detection. But the main purpose of this debug option is to detect double-activations (double call_rcu() use of a rcu_head before the callback is executed), which is correctly addressed here. This also detects potential internal RCU callback corruption, which would cause the callbacks to be executed twice. Signed-off-by: Mathieu Desnoyers <mathieu.desnoyers@efficios.com> CC: David S. Miller <davem@davemloft.net> CC: "Paul E. McKenney" <paulmck@linux.vnet.ibm.com> CC: akpm@linux-foundation.org CC: mingo@elte.hu CC: laijs@cn.fujitsu.com CC: dipankar@in.ibm.com CC: josh@joshtriplett.org CC: dvhltc@us.ibm.com CC: niv@us.ibm.com CC: tglx@linutronix.de CC: peterz@infradead.org CC: rostedt@goodmis.org CC: Valdis.Kletnieks@vt.edu CC: dhowells@redhat.com CC: eric.dumazet@gmail.com CC: Alexey Dobriyan <adobriyan@gmail.com> Signed-off-by: Paul E. McKenney <paulmck@linux.vnet.ibm.com> Reviewed-by: Lai Jiangshan <laijs@cn.fujitsu.com>
2010-04-17 20:48:42 +08:00
return 0;
}
rcu_barrier();
rcu_barrier_sched();
rcu_barrier_bh();
debug_object_free(head, &rcuhead_debug_descr);
return 1;
default:
return 0;
}
}
/**
* init_rcu_head_on_stack() - initialize on-stack rcu_head for debugobjects
* @head: pointer to rcu_head structure to be initialized
*
* This function informs debugobjects of a new rcu_head structure that
* has been allocated as an auto variable on the stack. This function
* is not required for rcu_head structures that are statically defined or
* that are dynamically allocated on the heap. This function has no
* effect for !CONFIG_DEBUG_OBJECTS_RCU_HEAD kernel builds.
*/
void init_rcu_head_on_stack(struct rcu_head *head)
{
debug_object_init_on_stack(head, &rcuhead_debug_descr);
}
EXPORT_SYMBOL_GPL(init_rcu_head_on_stack);
/**
* destroy_rcu_head_on_stack() - destroy on-stack rcu_head for debugobjects
* @head: pointer to rcu_head structure to be initialized
*
* This function informs debugobjects that an on-stack rcu_head structure
* is about to go out of scope. As with init_rcu_head_on_stack(), this
* function is not required for rcu_head structures that are statically
* defined or that are dynamically allocated on the heap. Also as with
* init_rcu_head_on_stack(), this function has no effect for
* !CONFIG_DEBUG_OBJECTS_RCU_HEAD kernel builds.
*/
void destroy_rcu_head_on_stack(struct rcu_head *head)
{
debug_object_free(head, &rcuhead_debug_descr);
}
EXPORT_SYMBOL_GPL(destroy_rcu_head_on_stack);
struct debug_obj_descr rcuhead_debug_descr = {
.name = "rcu_head",
.fixup_init = rcuhead_fixup_init,
.fixup_activate = rcuhead_fixup_activate,
.fixup_free = rcuhead_fixup_free,
};
EXPORT_SYMBOL_GPL(rcuhead_debug_descr);
#endif /* #ifdef CONFIG_DEBUG_OBJECTS_RCU_HEAD */
#if defined(CONFIG_TREE_RCU) || defined(CONFIG_TREE_PREEMPT_RCU) || defined(CONFIG_RCU_TRACE)
void do_trace_rcu_torture_read(char *rcutorturename, struct rcu_head *rhp)
{
trace_rcu_torture_read(rcutorturename, rhp);
}
EXPORT_SYMBOL_GPL(do_trace_rcu_torture_read);
#else
#define do_trace_rcu_torture_read(rcutorturename, rhp) do { } while (0)
#endif